DSpace Repository

Evaluation of the different exposure parameters for the accurate diagnosis of peri-implantitis severity in digital panoramic radiography

Show simple item record

dc.contributor.author Sadik, Elif
dc.contributor.author Gokmenoglu, Ceren
dc.contributor.author Altun, Gokcen
dc.contributor.author Kara, Cankat
dc.date.accessioned 2024-03-15T12:04:26Z
dc.date.available 2024-03-15T12:04:26Z
dc.date.issued 2023
dc.identifier.citation Sadik, E., Gokmenoglu, C., Altun, G., Kara, C. (2023). Evaluation of the different exposure parameters for the accurate diagnosis of peri-implantitis severity in digital panoramic radiography. Med. Oral Patol. Oral Cir. Bucal, 28(1), E16-E24. https://doi.org/10.4317/medoral.25501 en_US
dc.identifier.issn 1698-6946
dc.identifier.uri http://dx.doi.org/10.4317/medoral.25501
dc.identifier.uri https://www.webofscience.com/wos/woscc/full-record/WOS:000921613200003
dc.identifier.uri http://earsiv.odu.edu.tr:8080/xmlui/handle/11489/4620
dc.description WoS Categories: Dentistry, Oral Surgery & Medicine en_US
dc.description Web of Science Index: Science Citation Index Expanded (SCI-EXPANDED) en_US
dc.description Research Areas: Dentistry, Oral Surgery & Medicine en_US
dc.description.abstract Background: To evaluate the accuracy of the diagnosis of peri-implant bone defects' severities in digital pan-oramic radiographs obtained at different tube voltage and/or tube current settings. Material and Methods: Two different sizes of peri-implant bone defects (type 1 and type 2) were prepared after the implants were inserted into 29 bovine rib blocks. Digital panoramic radiographs were obtained at eight different tube voltage and/or tube current settings for all rib blocks. Implant images were cropped separately. The average intensity value (AIV) of cropped images were analyzed using Adobe Photoshop CC software. The Kruskal-Wallis H test was used to compare AIVs. All cropped images were evaluated using a five-point Likert scale for the likeli-hood of a bone defect being absent or present. The weighted kappa values were calculated to compare observer agreement and ROC analysis was performed to determine the appropriate exposure parameters. Results: The lowest AIV was obtained at 72 kV/6.3 mA (92.162 +/- 16.016), and the highest AIV was obtained at 60 kV/3.2 mA (179.050 +/- 13.823). The Kruskal-Wallis H test showed significant differences in the AIVs according to the exposure parameters (p<0.001). The kappa coefficient for the inter-observer agreement was excellent (0.864, p<0.001). The AUC values for type 1 defects ranged from 0.778 and 0.860; for type 2 defects ranged from 0.920 and 0.967. The AUC value of type 1 defects was slightly better in panoramic images obtained with high kV and low mA levels (72 kV/3.2 mA), compared to others. Conclusions: In daily clinical routine, peri-implant bone defects might be evaluated by panoramic radiographs obtained with all kV and mA values tested. However, to avoid misdiagnosing and for better accuracy, panoramic radiographs obtained with high kV and low mA levels suitable for patients should be used, especially in the detec-tion of small or initial bone defects. en_US
dc.description.sponsorship Ordu University Scientific Research Committee [AP-1722] en_US
dc.language.iso eng en_US
dc.publisher MEDICINA ORAL S L-VALENCIA en_US
dc.relation.isversionof 10.4317/medoral.25501 en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.subject Dental implant, panoramic radiography, peri-implantitis, diagnosis en_US
dc.subject BEAM COMPUTED-TOMOGRAPHY, IN-VITRO EVALUATION, DOSE REDUCTION, PERIAPICAL RADIOGRAPHY, DENTAL IMPLANTS, BONE DEFECTS, RADIOLUCENCIES, DENSITY en_US
dc.title Evaluation of the different exposure parameters for the accurate diagnosis of peri-implantitis severity in digital panoramic radiography en_US
dc.type article en_US
dc.relation.journal MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL en_US
dc.contributor.department Ordu Üniversitesi en_US
dc.contributor.authorID 0000-0002-3803-7189 en_US
dc.identifier.volume 28 en_US
dc.identifier.issue 1 en_US
dc.identifier.startpage E16 en_US
dc.identifier.endpage E24 en_US


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account