DSpace Repository

Effects of denture cleaning solutions on the retention of Hader bar clips

Show simple item record

dc.contributor.author Kucukekenci, Ahmet Serkan
dc.contributor.author Dede, Dogu Omur
dc.contributor.author Celik, Ersan
dc.date.accessioned 2023-01-06T10:43:49Z
dc.date.available 2023-01-06T10:43:49Z
dc.date.issued 2021
dc.identifier.citation Kucukekenci, AS., Dede, DO., Celik, E. (2021). Effects of denture cleaning solutions on the retention of Hader bar clips. Journal of Prosthetic Dentistry, 125(2), -.Doi:10.1016/j.prosdent.2020.09.026 en_US
dc.identifier.isbn 0022-3913
dc.identifier.isbn 1097-6841
dc.identifier.uri http://dx.doi.org/10.1016/j.prosdent.2020.09.026
dc.identifier.uri https://www.webofscience.com/wos/woscc/full-record/WOS:000616139600028
dc.identifier.uri https://pubmed.ncbi.nlm.nih.gov/33198989
dc.identifier.uri http://earsiv.odu.edu.tr:8080/xmlui/handle/11489/3371
dc.description WoS Categories : Dentistry, Oral Surgery & Medicine Web of Science Index : Science Citation Index Expanded (SCI-EXPANDED) Research Areas : Dentistry, Oral Surgery & Medicine en_US
dc.description.abstract Statement of problem. The clinical performance of implant-retained overdentures (IODs) with plastic bar clips made of different materials in the same design and dimensions may vary according to the patient's daily home care procedures. However, information about the effects of denture cleaning solutions on the retention of Hader bar clips is lacking. Purpose. The purpose of this in vitro study was to evaluate the retention of Hader bar clips made of different polymers after being soaked in denture cleaning solutions. Material and methods. Ninety Hader bar clips made of polyamide (PA, n=30), polytetrafluoroethylene (PTFE, n=30), and polyetherketoneketone (PEKK, n=30) materials were tested. Two multiunit abutments were screwed onto the implant analogs and embedded into an acrylic resin block in a standardized position. The digital scanning of the abutments was acquired, and the bar patrix of each material system milled from a cobalt-chromium (Co-Cr) alloy disk by using computer-aided design and computer-aided manufacturing (CAD-CAM). After the milled bar patrices were screwed onto abutments and the metal housings of the bar clips were embedded into acrylic resin blocks, they were connected passively at the same angulation to a universal testing machine. The initial retention values of all Hader bar clips were measured, and each material system was divided into 3 subgroups (n=10) before soaking in the cleaning solutions: distilled water (DW), 5% sodium hypochlorite (NaOCl), or sodium bicarbonate-sodium perborate (SBSP). Each material was soaked for the equivalent of 3 months of clinical use. The final retention values of each Hader bar clip were measured. The data were statistically analyzed by using a 2-way analysis of variance (ANOVA), the Tukey honestly significant difference (HSD) test, and the paired sample t test (alpha=.05). Results. The 2-way ANOVA showed that the denture cleaning solution, the clip material, and their interactions led to significantly different retention values (P<.001). A decrease was observed for the retention values of all test groups after soaking in the cleaning solutions (P<.05). No retention was observed for the PTFE clips after soaking in the 5% NaOCI solution. Conclusions. The denture cleaning solutions negatively affected the retention of Hader bar clips, regardless of the type of solution and clip material. The 5% NaOCI solution not only decreased the retention of PTFE clips but also completely degraded it. It is recommended that 5% NaOCI solution be avoided for the daily care of IODs with PTFE clips. en_US
dc.description.sponsorship Funding Orgs : Scientific Research Projects Department of Ordu University [HD-1621] Funding Name Preferred : Scientific Research Projects Department of Ordu University Funding Text : Supported by the Scientific Research Projects Department of Ordu University by ``HD-1621'' numbered support project. en_US
dc.language.iso eng en_US
dc.publisher MOSBY-ELSEVIER NEW YORK en_US
dc.relation.isversionof 10.1016/j.prosdent.2020.09.026 en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.subject MANDIBULAR OVERDENTURES; LOCATOR ATTACHMENTS; CLINICAL-EVALUATION; SURFACE-ROUGHNESS; CANDIDA-ALBICANS; BALL-SOCKET; IN-VITRO; IMPLANTS; CLEANERS; TRIAL en_US
dc.title Effects of denture cleaning solutions on the retention of Hader bar clips en_US
dc.type article en_US
dc.relation.journal JOURNAL OF PROSTHETIC DENTISTRY en_US
dc.contributor.department Ordu Üniversitesi en_US
dc.contributor.authorID 0000-0003-1021-5702 en_US
dc.identifier.volume 125 en_US
dc.identifier.issue 2 en_US


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account