DSpace Repository

Early-Loaded One-Stage Implants Retaining Mandibular Overdentures by Two Different Mechanisms: 5-Year Results

Show simple item record

dc.contributor.author Akca, Kivanc
dc.contributor.author Cavusoglu, Yeliz
dc.contributor.author Sagirkaya, Elcin
dc.contributor.author Cehreli, Murat Cavit
dc.date.accessioned 2022-09-08T11:46:52Z
dc.date.available 2022-09-08T11:46:52Z
dc.date.issued 2013
dc.identifier.uri http://doi.org/10.11607/jomi.2994
dc.identifier.uri http://earsiv.odu.edu.tr:8080/xmlui/handle/11489/3237
dc.description.abstract Purpose: To compare the biologic and prosthetic outcomes of implants loaded early to retain mandibular overdentures by means of two different attachment systems. Materials and Methods: Patients were screened according to specific inclusion/exclusion criteria and randomly allocated to treatment groups involving two-implant-supported early loaded mandibular overdentures retained by ball attachments or Locator attachments. Marginal bone loss, Plaque Index, peri-implant infection, Bleeding Index, prosthetic complications, and Kaplan-Meier survival estimates of the groups were assessed at the 5-year recall. Results: Among the 29 patients (58 implants) who completed the study, one implant was lost during healing; all implants survived after prosthesis delivery. Bone loss in the ball attachment group (0.77 +/- 0.05 mm) was significantly greater than that in the Locator group (0.59 +/- 0.03 mm). The Plaque and Bleeding indices of both groups were comparable, and peri-implant inflammation scores in both groups were zero for all implants. The frequencies of activation of the matrix, replacement of the matrix, and denture reline in the ball attachment group were significantly higher than those observed in the Locator group. While assessments for the absence of any complication showed that the 1- and 3-year Kaplan-Meier survival probabilities of both groups were comparable, when activation of the retainer was excluded, survival probabilities of the ball attachment group were higher. Conclusions: The biologic outcomes of early loaded mandibular overdentures retained by ball attachments or Locators were comparable. Although the frequency of prosthetic complications with ball attachments was higher, this did not decrease the survival probability for the treatment. en_US
dc.language.iso eng en_US
dc.publisher QUINTESSENCE PUBLISHING CO INC4350 CHANDLER DRIVE, HANOVER PARK, IL 60133 en_US
dc.relation.isversionof 10.11607/jomi.2994 en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.subject ball attachment implant-retained overdenture Locator marginal bone loss prosthetic complication en_US
dc.title Early-Loaded One-Stage Implants Retaining Mandibular Overdentures by Two Different Mechanisms: 5-Year Results en_US
dc.type article en_US
dc.relation.journal INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS en_US
dc.contributor.department Ordu Üniversitesi en_US
dc.contributor.authorID 0000-0003-3013-2533 en_US
dc.contributor.authorID 0000-0003-1164-5069 en_US
dc.identifier.volume 28 en_US
dc.identifier.issue 3 en_US
dc.identifier.startpage 824 en_US
dc.identifier.endpage 830 en_US