dc.description.abstract Aim: Among cardiovascular diseases, pulmonary embolism (PE) is a serious emergency with high mortality. Right ventricular dysfunction due to an excessive increase in pulmonary artery pressure is considered a major cause of death in vigorous PE. We aimed to assess the predictive value of computed tomographic pulmonary angiography (CTPA)-based morphometric measurements of right heart function in the diagnosis of PE. Materials and Methods: This is a retrospective, case-controlled study. A total of 198 cases were included in the study during the study phase. CTPA results of 102 patients with PE were recorded, and the patients were grouped according to clot localisation. The diameters of the inferior vena cava (IVCA), aorta, pulmonary artery and right and left ventricles were assessed. Results: IVCA area/aortic area significantly predicted embolism in the main pulmonary artery [area under the curve (AUC)=0.957, p<0.001]. The optimal cut-off value was 1.22 with 88% sensitivity and 90% specificity. IVCA diameter/aortic diameter significantly predicted embolism in the main pulmonary artery (AUC=0.955, p<0.001). The optimal cut-off value was 1.1 with 89% sensitivity and 88% specificity. Conclusion: Our study illustrated a remarkable association between the existence and dispersion of PE and morphometric changes in IVCA and aortic ratio parameters measured using CTPA. en_US
dc.language.iso eng en_US
dc.publisher EMERGENCY MEDICINE PHYSICIANS ASSOC TURKEY, YUKARI AYRANCI GLERYUZ SK NO 26-19, ANKARA, CANKAYA 06550, TURKEY en_US
dc.relation.isversionof 10.4274/eajem.galenos.2020.26122 en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.subject Pulmonary embolism; inferior vena cava diameter; aortic diameter en_US
dc.subject Pulmonary embolism; inferior vena cava diameter; aortic diameter en_US
dc.title Evaluation of Inferior Vena Cava/Abdominal Aorta Diameter Index in Pulmonary Embolism en_US
dc.type article en_US
dc.relation.journal EURASIAN JOURNAL OF EMERGENCY MEDICINE en_US
dc.contributor.department Ordu Üniversitesi en_US
dc.contributor.authorID 0000-0001-7468-4159 en_US
dc.contributor.authorID 0000-0002-9097-1024 en_US
dc.identifier.volume 19 en_US
dc.identifier.issue 2 en_US
dc.identifier.startpage 82 en_US
dc.identifier.endpage 88 en_US


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account