dc.description.abstract |
Purpose The purpose of this study is to quantify the motion dynamics of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Methods Three physical models of Newton's and Stokes's laws with(out) air resistance in the calm air are used to determine the falling time and velocity regimes of SARS-CoV-2 with(out) a respiratory water droplet of 1 to 2000 micrometers (mu m) in diameter of an infected person of 0.5 to 2.6 m in height. Results The horizontal distance travelled by SARS-CoV-2 in free fall from 1.7 m was 0.88 m due to breathing or talking and 2.94 m due to sneezing or coughing. According to Newton's laws of motion with air resistance, its falling velocity and time from 1.7 m were estimated at 3.95 x 10(-2)m s(-1)and 43 s, respectively. Large droplets > 100 mu m reached the ground from 1.7 m in less than 1.6 s, while the droplets >= 30 mu m fell within 4.42 s regardless of the human height. Based on Stokes's law, the falling time of the droplets encapsulating SARS-CoV-2 ranged from 4.26 x 10(-3)to 8.83 x 10(4) s as a function of the droplet size and height. Conclusion The spread dynamics of the COVID-19 pandemic is closely coupled to the falling dynamics of SARS-CoV-2 for which Newton's and Stokes's laws appeared to be applicable mostly to the respiratory droplet size >= 237.5 mu m and <= 237.5 mu m, respectively. An approach still remains to be desired so as to better quantify the motion of the nano-scale objects. |
en_US |
dc.language.iso |
eng |
en_US |
dc.publisher |
SPRINGER HEIDELBERG, TIERGARTENSTRASSE 17, D-69121 HEIDELBERG, GERMANY |
en_US |
dc.relation.isversionof |
10.1007/s40846-020-00575-y |
en_US |
dc.rights |
info:eu-repo/semantics/openAccess |
en_US |
dc.subject |
2019-nCoV; SARS-CoV-2; COVID-19; Newton's laws; Stokes's law |
en_US |
dc.title |
Falling Dynamics of SARS-CoV-2 as a Function of Respiratory Droplet Size and Human Height |
en_US |
dc.type |
article |
en_US |
dc.relation.journal |
JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING |
en_US |
dc.contributor.department |
Ordu Üniversitesi |
en_US |
dc.contributor.authorID |
0000-0002-4699-4595 |
en_US |
dc.contributor.authorID |
0000-0003-1099-4363 |
en_US |
dc.contributor.authorID |
0000-0003-3552-5459 |
en_US |
dc.identifier.volume |
40 |
en_US |
dc.identifier.issue |
6 |
en_US |
dc.identifier.startpage |
880 |
en_US |
dc.identifier.endpage |
886 |
en_US |