DSpace Repository

Does Sterilization Affect the Push Out Bond Strength of Experimental Dentin Posts?

Show simple item record

dc.contributor.author Dede, Dogu Omur
dc.contributor.author Sanal, Fatma Aye
dc.contributor.author Tulga, Ayca
dc.date.accessioned 2022-08-16T06:10:00Z
dc.date.available 2022-08-16T06:10:00Z
dc.date.issued 2019
dc.identifier.uri http://doi.org/10.15517/IJDS.V21I2.36506
dc.identifier.uri http://earsiv.odu.edu.tr:8080/xmlui/handle/11489/1708
dc.description.abstract The purpose of this preliminary study is to evaluate the push-out bond strength (PBS) of experimental dentin posts (EDPs) obtained from human and bovine teeth sterilized by autoclaving and gamma radiation. Eighty-four mandibulary premolars were obturated and divided into three post groups: the glass fiber group (Fb) human EDP group (Hm) and the bovine EDP group (Bv). Three subgroups (n=12) were obtained for each EDP groups according to the sterilization methods; no sterilization (Cnt), steam autoclaving (Aut), and gamma radiation (Rad) a total dose of 25 kGy. All posts were cemented to root canals using a dual cured resin cement (Panavia SA). After the micro slices (1 mm in thickness) were obtained of each subgroup, PBS test was performed. Data were analyzed using two-way ANOVA and Tukey's multiple comparison tests (alpha=.05). The post type and sterilization method was significantly effective on the PBS values according to the ANOVA (P<.001). No sterilization apllied EDP groups showed significantly higher PBS values than the sterilized groups (P<.001). Bv_Cnt (9.42 +/- 1.31) showed significantly lower PBS values than both Fb (12.36 +/- 1.54) and Hm_Cnt (11.06 +/- 1.38) groups (P<.001). Both steam autoclaving and gamma radiation affect the PBS values and fracture modes of EDPs negatively. The bovine EDPs are not as effective as human EDPs with regard to the PBS to the root dentin. en_US
dc.language.iso eng en_US
dc.publisher UNIV COSTA RICA, FAC ODONTOLOGIA, CIUDAD UNIV RODRIGO FACIO, SAN JOSE, 2050, COSTA RICA en_US
dc.relation.isversionof 10.15517/IJDS.V21I2.36506 en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.subject Dentin post; Gamma radiation; Steam autoclaving; Push-out bond strength en_US
dc.title Does Sterilization Affect the Push Out Bond Strength of Experimental Dentin Posts? en_US
dc.type article en_US
dc.relation.journal ODOVTOS INTERNATIONAL JOURNAL OF DENTAL SCIENCES en_US
dc.contributor.department Ordu Üniversitesi en_US
dc.identifier.volume 21 en_US
dc.identifier.issue 2 en_US
dc.identifier.startpage 63 en_US
dc.identifier.endpage 72 en_US


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account