DSpace Repository

Effect of Magnetic Resonance Applications on Dental Amalgam Phase Changes

Show simple item record

dc.contributor.author Alkurt, Meryem Toraman
dc.contributor.author Cakmak, Mehmet
dc.contributor.author Peker, Ilkay
dc.contributor.author Sadik, Elif
dc.date.accessioned 2022-08-16T05:30:40Z
dc.date.available 2022-08-16T05:30:40Z
dc.date.issued 2016
dc.identifier.uri http://doi.org/10.2174/1573405612666151203203427
dc.identifier.uri https://www.researchgate.net/publication/287122732_Effect_of_Magnetic_Resonance_Applications_on_Dental_Amalgam_Phase_Changes
dc.identifier.uri http://earsiv.odu.edu.tr:8080/xmlui/handle/11489/1560
dc.description.abstract Aim: The aim of this study was to examine the potential for low-versus high-field strength magnetic resonance applications to effect phase changes in high-copper dental amalgam as detected by X-ray diffraction (XRD) analysis. Materials and Methods: Disk-shaped samples (5 x 1 mm(2)) of amalgam filling were prepared (n = 90) and were thermocycled for 1000 cycles. The samples were then divided into three groups that were exposed to a 0.2 tesla or a 1.5 tesla magnetic field, or received no magnetic field exposure as a control. The samples were subsequently examined by XRD for phase determination 1, 7, and 30 days later. Results: The relationships between the gama, gama1, and eta phases, as well as the mercury peak intensities, were statistically analyzed using analysis of variance and the Kruskal Wallis test. No statistically significant differences were observed (p > 0.05). There were also no significant time-dependent differences observed between the gama, gama1, and eta phases, or in the mercury peak intensities, of the groups, according to the Friedman test (p > 0.05). Conclusion: The results of this study indicate that exposure to a magnetic field via magnetic resonance imaging does not affect the structure of dental amalgam. en_US
dc.language.iso eng en_US
dc.publisher BENTHAM SCIENCE PUBL LTD, EXECUTIVE STE Y-2, PO BOX 7917, SAIF ZONE, 1200 BR SHARJAH, U ARAB EMIRATES en_US
dc.relation.isversionof 10.2174/1573405612666151203203427 en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.subject Magnetic resonance imaging; dental amalgam; x-ray diffraction en_US
dc.subject RAY PHOTOELECTRON-SPECTROSCOPY; FIELD; EXPOSURE; DISEASES; SAFETY; ALLOY en_US
dc.title Effect of Magnetic Resonance Applications on Dental Amalgam Phase Changes en_US
dc.type article en_US
dc.relation.journal CURRENT MEDICAL IMAGING REVIEWS en_US
dc.contributor.department Ordu Üniversitesi en_US
dc.contributor.authorID 0000-0003-3382-2951 en_US
dc.identifier.volume 12 en_US
dc.identifier.issue 1 en_US
dc.identifier.startpage 59 en_US
dc.identifier.endpage 66 en_US