DSpace Repository

Is bone density or implant design more important in implant stress formation in patients with bruxism?

Show simple item record

dc.contributor.author Ayranci, Ferhat
dc.contributor.author Omezli, M. Melih
dc.contributor.author Sivrikaya, Efe Can
dc.date.accessioned 2022-08-16T05:21:24Z
dc.date.available 2022-08-16T05:21:24Z
dc.date.issued 2017
dc.identifier.uri http://doi.org/10.1080/13102818.2017.1376597
dc.identifier.uri https://www.tandfonline.com/doi/full/10.1080/13102818.2017.1376597
dc.identifier.uri http://earsiv.odu.edu.tr:8080/xmlui/handle/11489/1535
dc.description.abstract The aim of this study was to compare the stresses on cylindrical and conical dental implants under heavy bruxing forces, in D1 and D4 bone densities, using three-dimensional finite element analysis (FEA). Eight different stress models were created according to implant design (cylindrical or conical), bone density (D1 or D4) and load (1000N, vertical or oblique). The von Mises stresses for each model were compared using FEA. The obtained results showed that D1 bone density and vertical force were associated with the least stress on the implant. Bone density was more important than implant design in stress formation. The results from the two implant types were very similar. The von Mises stress values were greater in the neck region of the implant. We suggest that the implant region should be considered firstly for less stress on the implant. en_US
dc.language.iso eng en_US
dc.publisher TAYLOR & FRANCIS LTD, 2-4 PARK SQUARE, MILTON PARK, ABINGDON OR14 4RN, OXON, ENGLAND en_US
dc.relation.isversionof 10.1080/13102818.2017.1376597 en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.subject Density; dental implant; design; finite element analysis en_US
dc.subject FINITE-ELEMENT-ANALYSIS; DENTAL IMPLANTS; FAILURES; MULTICENTER; MAXILLARY; SURVIVAL en_US
dc.title Is bone density or implant design more important in implant stress formation in patients with bruxism? en_US
dc.type article en_US
dc.relation.journal BIOTECHNOLOGY & BIOTECHNOLOGICAL EQUIPMENT en_US
dc.contributor.department Ordu Üniversitesi en_US
dc.contributor.authorID 0000-0001-6798-7610 en_US
dc.identifier.volume 31 en_US
dc.identifier.issue 6 en_US
dc.identifier.startpage 1221 en_US
dc.identifier.endpage 1225 en_US


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account