Biomechanical comparison of osteosynthesis with poly-L-lactic acid and titanium screw in intracapsular condylar fracture fixation: An experimental study

Show simple item record

dc.contributor.author Dayi, E.
dc.contributor.author Omezli, M. M.
dc.contributor.author Polat, M. E.
dc.contributor.author Torul, D.
dc.date.accessioned 2022-08-16T05:19:41Z
dc.date.available 2022-08-16T05:19:41Z
dc.date.issued 2015
dc.identifier.uri http://doi.org/10.4103/1119-3077.158946
dc.identifier.uri http://earsiv.odu.edu.tr:8080/xmlui/handle/11489/1528
dc.description.abstract Background and Aims: The aim of this study was to compare the biomechanical stability of poly-L-lactic acid and titanium screws in the fixation of intracapsular condylar fractures, in 10 polyurethane hemimandibles. Materials and Methods: Artificial intracapsular fractures were created with a steel disk and electronic micromotor. The first group was fixed with 15 mm long self-tapping 2.0 mm system titanium screws and the second group was fixed with 15 mm long 2.4 mm bioresorbable screws. Linear loads of 25, 50, 75, 100 N was applied in anteroposterior direction to the hemimandibles and the data were transmitted directly from the load cell to a computer that shows emergent results of material characteristics under same forces as a graphic containing force and displacement. Results: The results show that there were no significant differences between the two methods, with 25 N of loading. (P > 0,05) The difference became significant with a higher value of loading. Conclusion: The results suggest that treatment with a single resorbable screw is not functionally stable as a single titanium screw. en_US
dc.language.iso eng en_US
dc.publisher WOLTERS KLUWER MEDKNOW PUBLICATIONSWOLTERS KLUWER INDIA PVT LTD, A-202, 2ND FLR, QUBE, C T S NO 1498A-2 VILLAGE MAROL, ANDHERI EAST, MUMBAI 400059, INDIA en_US
dc.relation.isversionof 10.4103/1119-3077.158946 en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.subject Intracapsular condylar fracturesosteosynthesisscrew fixation en_US
dc.subject MANDIBULAR CONDYLERESORBABLE PINSDIACAPITULAR FRACTURESIN-VITROSHEEPHEADRESISTANCEREDUCTIONPLATES en_US
dc.title Biomechanical comparison of osteosynthesis with poly-L-lactic acid and titanium screw in intracapsular condylar fracture fixation: An experimental study en_US
dc.type article en_US
dc.relation.journal NIGERIAN JOURNAL OF CLINICAL PRACTICE en_US
dc.contributor.department Ordu Üniversitesi en_US
dc.contributor.authorID 0000-0002-6606-6593 en_US
dc.contributor.authorID 0000-0003-2323-606X en_US
dc.identifier.volume 18 en_US
dc.identifier.issue 5 en_US
dc.identifier.startpage 589 en_US
dc.identifier.endpage 593 en_US


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account