dc.description.abstractBu araştırmada, türbin olarak kullanılan santrifüj pompanın jeneratör olarak kullanılan asenkron makinesinin, şebekeden izole olarak çalışırken değişken yük koşullarındaki performansının yükseltilmesi için elektronik kontrol kartı tasarlanmıştır. Kendinden ikazlı çalışan üç fazlı asenkron makine ile tek fazlı yüklerin beslenmesi incelenmiş balast yük sürücü kartı hazırlanmış ve test edilmiştir. Yük kontrol kartının asenkron jeneratör uç gerilimini kontrol etmesi için PID kontrol sistemi kullanmıştır. PID kontrolü algoritmasında balast yükün oransal kontrolünü sağlayan PWM modülasyonun başarılı şekilde çalıştığı ve jeneratör çıkış gerilimini istenilen gerilim seviyesinde ve frekansında tutabildiği tespit edilmiştir. Kontrol ve sürücü kartının oluşturduğu harmonik bozulmanın limitler dahilinde olduğu ve jeneratör sargılarında fazladan bir ısınmaya yol açmadığı tespit edilmiştir.,In this research, the electronic load control unit has designed on offline asynchronous generator at centrifugal pumps as turbines to improve electrical performance during variable load conditions. Feeding of single phase loads by self-excited three-phase asynchronous machines was examined and ballast load driver card was prepared and tested. The PID control system is used to control load driver board for adjusting generator terminal voltages. In the PID control algorithm, it has been determined that it works very successfully with PWM modulation which provides proportional control of ballast load and can keep generator output voltage at desired voltage level and frequency. İt has been found that the harmonic distortion caused by control and driver card is within the limits and does not cause any additional heating in the generator windings.en_US
dc.description.abstractIn this research, the electronic load control unit has designed on offline asynchronous generator at centrifugal pumps as turbines to improve electrical performance during variable load conditions. Feeding of single phase loads by self-excited three-phase asynchronous machines was examined and ballast load driver card was prepared and tested. The PID control system is used to control load driver board for adjusting generator terminal voltages. In the PID control algorithm, it has been determined that it works very successfully with PWM modulation which provides proportional control of ballast load and can keep generator output voltage at desired voltage level and frequency. İt has been found that the harmonic distortion caused by control and driver card is within the limits and does not cause any additional heating in the generator windings.en_US
dc.language.isoturen_US
dc.publisherFen Bilimleri Enstitüsüen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectFotovoltaik Sistem, Güneş Paneli, Güneş Takip Sistemien_US
dc.subjectPhotovoltaic Sistem, Solar Panel, Solar Tracker Sistemen_US
dc.titleTürbin Olarak Kullanılan Santrifüj Pompalarda Asenkron Jeneratörün Yük Kontrol Tasarımıen_US
dc.title.alternativeLOAD CONTROL DESIGN FOR ASYNCHRONOUS GENERATORS IN CENTRIFUGAL PUMPS USED AS TURBINESen_US
dc.typemasterThesisen_US
dc.contributor.departmentOrdu Üniversitesien_US
dc.contributor.departmentFen Bilimleri Enstitüsüen_US
Appears in Collections:Fen Bilimleri Enstitüsü

Files in This Item:
File Description SizeFormat 
10232115 (2).pdf102321154.5 MBAdobe PDFThumbnail
View/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.