Please use this identifier to cite or link to this item: http://earsiv.odu.edu.tr:8080/xmlui/handle/11489/5240
Full metadata record
DC FieldValueLanguage
dc.contributor.authorYilmaz, Burak-
dc.contributor.authorDede, Dogu Omur-
dc.contributor.authorDonmez, Mustafa Borga-
dc.contributor.authorKucukekenci, Ahmet Serkan-
dc.contributor.authorLu, Wei-En-
dc.contributor.authorSchumacher, Fernanda Lang-
dc.contributor.authorCakmak, Gulce-
dc.date.accessioned2024-03-26T06:53:19Z-
dc.date.available2024-03-26T06:53:19Z-
dc.date.issued2023-
dc.identifier.citationYilmaz, B., Dede, DÖ., Donmez, MB., Küçükekenci, AS., Lu, WE., Schumacher, FL., Çakmak, G. (2023). Comparison of intraoral and laboratory scanners to an industrial-grade scanner while analyzing the fabrication trueness of polymer and titanium complete-arch implant-supported frameworks. J. Dent., 138. https://doi.org/10.1016/j.jdent.2023.104697en_US
dc.identifier.issn0300-5712-
dc.identifier.issn1879-176X-
dc.identifier.urihttp://dx.doi.org/10.1016/j.jdent.2023.104697-
dc.identifier.urihttps://www.webofscience.com/wos/woscc/full-record/WOS:001119728900001-
dc.identifier.urihttp://earsiv.odu.edu.tr:8080/xmlui/handle/11489/5240-
dc.descriptionWoS Categories: Dentistry, Oral Surgery & Medicineen_US
dc.descriptionWeb of Science Index: Science Citation Index Expanded (SCI-EXPANDED)en_US
dc.descriptionResearch Areas: Dentistry, Oral Surgery & Medicineen_US
dc.description.abstractObjectives: To compare the scans of different intraoral scanners (IOSs) and laboratory scanners (LBSs) to those of an industrial-grade optical scanner by measuring deviations of complete-arch implant-supported frameworks from their virtual design file. Material and methods: Ten polyetheretherketone (PEEK) and 10 titanium (Ti) complete-arch implant-supported frameworks were milled from a master standard tessellation language (STL) file. An industrial-grade blue light scanner (AT), 2 LBSs (MT and E4), and 3 IOSs (PS, T3, and T4) were used to generate STL files of these frameworks. All STLs were imported into an analysis software (Geomagic Control X) and overall root mean square (RMS) values were calculated. Marginal surfaces of all STL files were then virtually isolated (Medit Link v 2.4.4) and marginal RMS values were calculated. Deviations in scans of tested scanners were compared with those in scans of AT by using a linear mixed effects model (alpha = 0.05). Results: When the scans of PEEK frameworks were considered, PS and T3 had similar overall RMS to those of AT (p >= .076). However, E4 and T4 had higher and MT had lower overall RMS than AT (p <= .002) with a maximum estimated mean difference of 13.41 mu m. When the scans of Ti frameworks were considered, AT had significantly lower overall RMS than tested scanners (p <= .010) with a maximum estimated mean difference of 31.35 mu m. Scans of tested scanners led to significantly higher marginal RMS than scans of AT (p <= .006) with a maximum estimated mean difference of 53.90 mu m for PEEK and 40.50 mu m for Ti frameworks. Conclusion: Only the PEEK framework scans of PS and T3 led to similar overall deviations to those of AT. However, scans of all tested scanners resulted in higher marginal deviations than those of AT scans. Clinical Significance: Scans performed by using PS and T3 may be alternatives to those of tested reference industrial scanner AT, for the overall fabrication trueness analysis of complete-arch implant-supported PEEK frameworks.en_US
dc.language.isoengen_US
dc.publisherELSEVIER SCI LTD-Londonen_US
dc.relation.isversionof10.1016/j.jdent.2023.104697en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectComplete -arch implant -supported, Deviation, Framework, Intraoral scanner, Laboratory scanneren_US
dc.titleComparison of intraoral and laboratory scanners to an industrial-grade scanner while analyzing the fabrication trueness of polymer and titanium complete-arch implant-supported frameworksen_US
dc.typearticleen_US
dc.relation.journalJOURNAL OF DENTISTRYen_US
dc.contributor.departmentOrdu Üniversitesien_US
dc.contributor.authorID0000-0002-3094-7487en_US
dc.contributor.authorID0000-0003-1021-5702en_US
dc.contributor.authorID0000-0002-5724-8918en_US
dc.identifier.volume138en_US
Appears in Collections:Protetik Diş Tedavisi

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.