Please use this identifier to cite or link to this item: http://earsiv.odu.edu.tr:8080/xmlui/handle/11489/4620
Full metadata record
DC FieldValueLanguage
dc.contributor.authorSadik, Elif-
dc.contributor.authorGokmenoglu, Ceren-
dc.contributor.authorAltun, Gokcen-
dc.contributor.authorKara, Cankat-
dc.date.accessioned2024-03-15T12:04:26Z-
dc.date.available2024-03-15T12:04:26Z-
dc.date.issued2023-
dc.identifier.citationSadik, E., Gokmenoglu, C., Altun, G., Kara, C. (2023). Evaluation of the different exposure parameters for the accurate diagnosis of peri-implantitis severity in digital panoramic radiography. Med. Oral Patol. Oral Cir. Bucal, 28(1), E16-E24. https://doi.org/10.4317/medoral.25501en_US
dc.identifier.issn1698-6946-
dc.identifier.urihttp://dx.doi.org/10.4317/medoral.25501-
dc.identifier.urihttps://www.webofscience.com/wos/woscc/full-record/WOS:000921613200003-
dc.identifier.urihttp://earsiv.odu.edu.tr:8080/xmlui/handle/11489/4620-
dc.descriptionWoS Categories: Dentistry, Oral Surgery & Medicineen_US
dc.descriptionWeb of Science Index: Science Citation Index Expanded (SCI-EXPANDED)en_US
dc.descriptionResearch Areas: Dentistry, Oral Surgery & Medicineen_US
dc.description.abstractBackground: To evaluate the accuracy of the diagnosis of peri-implant bone defects' severities in digital pan-oramic radiographs obtained at different tube voltage and/or tube current settings. Material and Methods: Two different sizes of peri-implant bone defects (type 1 and type 2) were prepared after the implants were inserted into 29 bovine rib blocks. Digital panoramic radiographs were obtained at eight different tube voltage and/or tube current settings for all rib blocks. Implant images were cropped separately. The average intensity value (AIV) of cropped images were analyzed using Adobe Photoshop CC software. The Kruskal-Wallis H test was used to compare AIVs. All cropped images were evaluated using a five-point Likert scale for the likeli-hood of a bone defect being absent or present. The weighted kappa values were calculated to compare observer agreement and ROC analysis was performed to determine the appropriate exposure parameters. Results: The lowest AIV was obtained at 72 kV/6.3 mA (92.162 +/- 16.016), and the highest AIV was obtained at 60 kV/3.2 mA (179.050 +/- 13.823). The Kruskal-Wallis H test showed significant differences in the AIVs according to the exposure parameters (p<0.001). The kappa coefficient for the inter-observer agreement was excellent (0.864, p<0.001). The AUC values for type 1 defects ranged from 0.778 and 0.860; for type 2 defects ranged from 0.920 and 0.967. The AUC value of type 1 defects was slightly better in panoramic images obtained with high kV and low mA levels (72 kV/3.2 mA), compared to others. Conclusions: In daily clinical routine, peri-implant bone defects might be evaluated by panoramic radiographs obtained with all kV and mA values tested. However, to avoid misdiagnosing and for better accuracy, panoramic radiographs obtained with high kV and low mA levels suitable for patients should be used, especially in the detec-tion of small or initial bone defects.en_US
dc.description.sponsorshipOrdu University Scientific Research Committee [AP-1722]en_US
dc.language.isoengen_US
dc.publisherMEDICINA ORAL S L-VALENCIAen_US
dc.relation.isversionof10.4317/medoral.25501en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectDental implant, panoramic radiography, peri-implantitis, diagnosisen_US
dc.subjectBEAM COMPUTED-TOMOGRAPHY, IN-VITRO EVALUATION, DOSE REDUCTION, PERIAPICAL RADIOGRAPHY, DENTAL IMPLANTS, BONE DEFECTS, RADIOLUCENCIES, DENSITYen_US
dc.titleEvaluation of the different exposure parameters for the accurate diagnosis of peri-implantitis severity in digital panoramic radiographyen_US
dc.typearticleen_US
dc.relation.journalMEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCALen_US
dc.contributor.departmentOrdu Üniversitesien_US
dc.contributor.authorID0000-0002-3803-7189en_US
dc.identifier.volume28en_US
dc.identifier.issue1en_US
dc.identifier.startpageE16en_US
dc.identifier.endpageE24en_US
Appears in Collections:Ağız, Diş ve Çene Radyolojisi

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.