Please use this identifier to cite or link to this item: http://earsiv.odu.edu.tr:8080/xmlui/handle/11489/4053
Full metadata record
DC FieldValueLanguage
dc.contributor.authorAlkan, Osman Firat-
dc.contributor.authorOy, Sibel Akkaya-
dc.date.accessioned2024-03-15T06:55:24Z-
dc.date.available2024-03-15T06:55:24Z-
dc.date.issued2023-
dc.identifier.citationAlkan, OF., Oy, SA. (2023). Usage of standard centrifugal pumps as an off-grid generator and performance analysis. J. Polytech., 26(3), 1091-1102. https://doi.org/10.2339/politeknik.905717en_US
dc.identifier.issn1302-0900-
dc.identifier.issn2147-9429-
dc.identifier.urihttp://dx.doi.org/10.2339/politeknik.905717-
dc.identifier.urihttps://www.webofscience.com/wos/woscc/full-record/WOS:000777559700001-
dc.identifier.urihttp://earsiv.odu.edu.tr:8080/xmlui/handle/11489/4053-
dc.descriptionWoS Categories: Engineering, Multidisciplinaryen_US
dc.descriptionWeb of Science Index: Emerging Sources Citation Index (ESCI)en_US
dc.descriptionResearch Areas: Engineeringen_US
dc.description.abstractUsing field-specific design turbine-generator equipment in rural areas and projects with hydraulic resources at micro scale reduces accessibility by increasing investment costs. Another alternative for projects that want to generate electricity with usable performance with limited financial resources is to use the standard centrifugal pump-motor set as a turbine-generator. This study aimed to design a load control system that can keep the energy quality deterioration in variable load situations within the desired limits and at the same time be installed with low cost , while the standard centrifugal pump-motor set is independent from the grid as a turbine-generator and feeding single-phase loads. It is focused on the use of a three-phase self-excited induction generator to feed one-phase loads, which has the advantage of easy excitation and stable operation, thus reducing the number and cost of the elements in the load control SN stem. PID algorithm has been created to enable the ballast load of the load control system to a stable operation at the calculated power. MATLAB SIMULINK program was used to test the design in computer environment. Then, the physical performance tests or the system, which was established in the experimental set environment, were also performed. The results of the measurements showed that the designed load control card keeps the generator output voltage and frequency at the desired output voltage and licquency, which reduces the change in the generator output voltage frequency from 16% to 1% and the voltage change from 34% to 3% during load changes. It has been determined that the response time of the load control card is between 40 and 150 ins during load shedding and unloading.en_US
dc.language.isoengen_US
dc.publisherGAZI UNIV-ANKARAen_US
dc.relation.isversionof10.2339/politeknik.905717en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectCentrifugal pumps, turbine, asynchronous generator, PIDen_US
dc.titleUsage of standard centrifugal pumps as an off-grid generator and performance analysisen_US
dc.typearticleen_US
dc.relation.journalJOURNAL OF POLYTECHNIC-POLITEKNIK DERGISIen_US
dc.contributor.departmentOrdu Üniversitesien_US
dc.identifier.volume26en_US
dc.identifier.issue3en_US
dc.identifier.startpage1091en_US
dc.identifier.endpage1102en_US
Appears in Collections:Deniz Bilimleri ve Teknolojisi

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.