Please use this identifier to cite or link to this item: http://earsiv.odu.edu.tr:8080/xmlui/handle/11489/4047
Full metadata record
DC FieldValueLanguage
dc.contributor.authorOzkan, Serkan-
dc.contributor.authorBuyuk, Suleyman Kutalmis-
dc.contributor.authorGok, Firat-
dc.contributor.authorBenkli, Yasin Atakan-
dc.date.accessioned2024-03-15T06:53:45Z-
dc.date.available2024-03-15T06:53:45Z-
dc.date.issued2022-
dc.identifier.citationÖzkan, S., Büyük, SK., Gök, F., Benkli, YA. (2022). Evaluation of reused orthodontic mini- implants on stability: An in-vivo study. Am. J. Orthod. Dentofac. Orthop., 162(5), 689-694. https://doi.org/10.1016/j.ajodo.2021.06.024en_US
dc.identifier.issn0889-5406-
dc.identifier.issn1097-6752-
dc.identifier.urihttp://dx.doi.org/10.1016/j.ajodo.2021.06.024-
dc.identifier.urihttps://www.webofscience.com/wos/woscc/full-record/WOS:000884789700023-
dc.identifier.urihttp://earsiv.odu.edu.tr:8080/xmlui/handle/11489/4047-
dc.descriptionWoS Categories: Dentistry, Oral Surgery & Medicineen_US
dc.descriptionWeb of Science Index: Science Citation Index Expanded (SCI-EXPANDED)en_US
dc.descriptionResearch Areas: Dentistry, Oral Surgery & Medicineen_US
dc.description.abstractIntroduction: During treatment, some patients may need to change the location of mini-implants (MIs). This study investigated the stability of MIs relocated to another position in the same patient using the periotest and torque device. Methods: Twenty-nine MIs were applied randomly to 1 side of the maxillary region, and torque and periotest values were recorded. The patients were followed-up at 4-week intervals, and periotest measurements were performed at each session. After recording the torque and periotest values in the fourth session, the MIs were removed. After applying the appropriate sterilization procedure, the same MIs were relocated to the contralateral side of the patients' jaw, and distalization was achieved using a similar procedure for the group of as-received MIs. Results: Negative correlations were obtained between the torque meter and periotest data for both MI groups. We observed no significant effect of the MI group on periotest mea-surements (P>0.05). The effect of the MI group on torque values and the interaction effect of the MI group and torque values were not statistically significant (P >0.05). Conclusions: It is possible to achieve similar stability values with as-received and retrieved MIs when appropriate cleaning and sterilization protocols are performed.en_US
dc.description.sponsorshipScientific Research Projects Commission of Ordu University; [AR-1528]en_US
dc.language.isoengen_US
dc.publisherMOSBY-ELSEVIER-NEW YORKen_US
dc.relation.isversionof10.1016/j.ajodo.2021.06.024en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectSODIUM-HYPOCHLORITE, PERIOTEST VALUES, ANCHORAGE, TORQUEen_US
dc.titleEvaluation of reused orthodontic mini- implants on stability: An in-vivo studyen_US
dc.typearticleen_US
dc.relation.journalAMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICSen_US
dc.contributor.departmentOrdu Üniversitesien_US
dc.identifier.volume162en_US
dc.identifier.issue5en_US
dc.identifier.startpage689en_US
dc.identifier.endpage694en_US
Appears in Collections:Ortodonti

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.