Please use this identifier to cite or link to this item: http://earsiv.odu.edu.tr:8080/xmlui/handle/11489/3611
Full metadata record
DC FieldValueLanguage
dc.contributor.authorKuralay, Filiz-
dc.contributor.authorDukar, Nilgun-
dc.contributor.authorBayramli, Yasar-
dc.date.accessioned2023-01-06T12:03:57Z-
dc.date.available2023-01-06T12:03:57Z-
dc.date.issued2021-
dc.identifier.citationKuralay, F., Dukar, N., Bayramli, Y. (2021). Designing functional materials: DNA/Poly(3,4-ethylenedioxythiophene) interfaces for advanced DNA direct electrochemistry and DNA-Drug interaction detection. Materials Science and Engineering B-Advanced Functional Solid-State Materials, 272, -.Doi:10.1016/j.mseb.2021.115382en_US
dc.identifier.isbn0921-5107-
dc.identifier.isbn1873-4944-
dc.identifier.urihttp://dx.doi.org/10.1016/j.mseb.2021.115382-
dc.identifier.urihttps://www.webofscience.com/wos/woscc/full-record/WOS:000686131900005-
dc.identifier.urihttp://earsiv.odu.edu.tr:8080/xmlui/handle/11489/3611-
dc.descriptionWoS Categories : Materials Science, Multidisciplinary; Physics, Condensed Matter Web of Science Index : Science Citation Index Expanded (SCI-EXPANDED) Research Areas : Materials Science; Physicsen_US
dc.description.abstractIn the present study, preparation of poly(3,4-ethylenedioxythiophene) coated pencil graphite electrode with the addition of multi-walled carbon nanotubes (MWCNTs) (PEDOT nanoelectrode, NE); incorporation of double-stranded deoxyribonucleic acid (dsDNA) onto NE (dsDNA/PEDOT NE); and the bio-application of dsDNA/PEDOT NE were described. PEDOT NEs were first used to immobilize dsDNA onto the electrode surfaces in a high efficiency to detect dsDNA with advanced oxidation signals. Afterwards, these functional biointerfaces were used for the investigation of DNA interaction with Mitomycin C (MC) and Paclitaxel (PTX) based on guanine and adenine oxidation signals. dsDNA/PEDOT NE was presented a linearity in the concentration of 1 mg L-1 to 50 mg L-1 for MC with a detection limit of 0.26 mg L-1 . The linear range was between 0.5 mg L-1 and 60 mg L-1 for PTX with a detection limit of 0.14 mg L-1 (n = 3). In addition, dsDNA/PEDOT NE was presented good stability.en_US
dc.language.isoengen_US
dc.publisherELSEVIER AMSTERDAMen_US
dc.relation.isversionof10.1016/j.mseb.2021.115382en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectPENCIL-GRAPHITE ELECTRODE; CARBON NANOTUBES; POLY 3,4-ETHYLENEDIOXYTHIOPHENE; DISPOSABLE ELECTRODES; GRAPHENE OXIDE; STRAIN SENSOR; URIC-ACID; BIOSENSORS; COMPOSITE; NANOCOMPOSITEen_US
dc.subjectFunctional surfaces; dsDNA; DNA-anticancer drug interaction; Electrochemistryen_US
dc.titleDesigning functional materials: DNA/Poly(3,4-ethylenedioxythiophene) interfaces for advanced DNA direct electrochemistry and DNA-Drug interaction detectionen_US
dc.typearticleen_US
dc.relation.journalMATERIALS SCIENCE AND ENGINEERING B-ADVANCED FUNCTIONAL SOLID-STATE MATERIALSen_US
dc.contributor.departmentOrdu Üniversitesien_US
dc.identifier.volume272en_US
Appears in Collections:Kimya

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.