Please use this identifier to cite or link to this item: http://earsiv.odu.edu.tr:8080/xmlui/handle/11489/3237
Full metadata record
DC FieldValueLanguage
dc.contributor.authorAkca, Kivanc-
dc.contributor.authorCavusoglu, Yeliz-
dc.contributor.authorSagirkaya, Elcin-
dc.contributor.authorCehreli, Murat Cavit-
dc.date.accessioned2022-09-08T11:46:52Z-
dc.date.available2022-09-08T11:46:52Z-
dc.date.issued2013-
dc.identifier.urihttp://doi.org/10.11607/jomi.2994-
dc.identifier.urihttp://earsiv.odu.edu.tr:8080/xmlui/handle/11489/3237-
dc.description.abstractPurpose: To compare the biologic and prosthetic outcomes of implants loaded early to retain mandibular overdentures by means of two different attachment systems. Materials and Methods: Patients were screened according to specific inclusion/exclusion criteria and randomly allocated to treatment groups involving two-implant-supported early loaded mandibular overdentures retained by ball attachments or Locator attachments. Marginal bone loss, Plaque Index, peri-implant infection, Bleeding Index, prosthetic complications, and Kaplan-Meier survival estimates of the groups were assessed at the 5-year recall. Results: Among the 29 patients (58 implants) who completed the study, one implant was lost during healing; all implants survived after prosthesis delivery. Bone loss in the ball attachment group (0.77 +/- 0.05 mm) was significantly greater than that in the Locator group (0.59 +/- 0.03 mm). The Plaque and Bleeding indices of both groups were comparable, and peri-implant inflammation scores in both groups were zero for all implants. The frequencies of activation of the matrix, replacement of the matrix, and denture reline in the ball attachment group were significantly higher than those observed in the Locator group. While assessments for the absence of any complication showed that the 1- and 3-year Kaplan-Meier survival probabilities of both groups were comparable, when activation of the retainer was excluded, survival probabilities of the ball attachment group were higher. Conclusions: The biologic outcomes of early loaded mandibular overdentures retained by ball attachments or Locators were comparable. Although the frequency of prosthetic complications with ball attachments was higher, this did not decrease the survival probability for the treatment.en_US
dc.language.isoengen_US
dc.publisherQUINTESSENCE PUBLISHING CO INC4350 CHANDLER DRIVE, HANOVER PARK, IL 60133en_US
dc.relation.isversionof10.11607/jomi.2994en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectball attachment implant-retained overdenture Locator marginal bone loss prosthetic complicationen_US
dc.titleEarly-Loaded One-Stage Implants Retaining Mandibular Overdentures by Two Different Mechanisms: 5-Year Resultsen_US
dc.typearticleen_US
dc.relation.journalINTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTSen_US
dc.contributor.departmentOrdu Üniversitesien_US
dc.contributor.authorID0000-0003-3013-2533en_US
dc.contributor.authorID0000-0003-1164-5069en_US
dc.identifier.volume28en_US
dc.identifier.issue3en_US
dc.identifier.startpage824en_US
dc.identifier.endpage830en_US
Appears in Collections:Protetik Diş Tedavisi

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.