Title: Early-Loaded One-Stage Implants Retaining Mandibular Overdentures by Two Different Mechanisms: 5-Year Results
Authors: Akca, Kivanc
Cavusoglu, Yeliz
Sagirkaya, Elcin
Cehreli, Murat Cavit
Ordu Üniversitesi
0000-0003-3013-2533
0000-0003-1164-5069
Keywords: ball attachment implant-retained overdenture Locator marginal bone loss prosthetic complication
Issue Date: 2013
Publisher: QUINTESSENCE PUBLISHING CO INC4350 CHANDLER DRIVE, HANOVER PARK, IL 60133
Abstract: Purpose: To compare the biologic and prosthetic outcomes of implants loaded early to retain mandibular overdentures by means of two different attachment systems. Materials and Methods: Patients were screened according to specific inclusion/exclusion criteria and randomly allocated to treatment groups involving two-implant-supported early loaded mandibular overdentures retained by ball attachments or Locator attachments. Marginal bone loss, Plaque Index, peri-implant infection, Bleeding Index, prosthetic complications, and Kaplan-Meier survival estimates of the groups were assessed at the 5-year recall. Results: Among the 29 patients (58 implants) who completed the study, one implant was lost during healing; all implants survived after prosthesis delivery. Bone loss in the ball attachment group (0.77 +/- 0.05 mm) was significantly greater than that in the Locator group (0.59 +/- 0.03 mm). The Plaque and Bleeding indices of both groups were comparable, and peri-implant inflammation scores in both groups were zero for all implants. The frequencies of activation of the matrix, replacement of the matrix, and denture reline in the ball attachment group were significantly higher than those observed in the Locator group. While assessments for the absence of any complication showed that the 1- and 3-year Kaplan-Meier survival probabilities of both groups were comparable, when activation of the retainer was excluded, survival probabilities of the ball attachment group were higher. Conclusions: The biologic outcomes of early loaded mandibular overdentures retained by ball attachments or Locators were comparable. Although the frequency of prosthetic complications with ball attachments was higher, this did not decrease the survival probability for the treatment.
URI: http://doi.org/10.11607/jomi.2994
http://earsiv.odu.edu.tr:8080/xmlui/handle/11489/3237
Appears in Collections:Protetik Diş Tedavisi

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.