Please use this identifier to cite or link to this item:
http://earsiv.odu.edu.tr:8080/xmlui/handle/11489/2649
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Canakci, Ebru | - |
dc.contributor.author | Hanci, Volkan | - |
dc.contributor.author | Karakahya, Refika Hande | - |
dc.contributor.author | Tas, Nilay | - |
dc.contributor.author | Yagan, Ozgur | - |
dc.contributor.author | Yurtlu, Bulent Serhan | - |
dc.date.accessioned | 2022-08-17T07:00:08Z | - |
dc.date.available | 2022-08-17T07:00:08Z | - |
dc.date.issued | 2015 | - |
dc.identifier.uri | https://pubmed.ncbi.nlm.nih.gov/26564297/ | - |
dc.identifier.uri | https://www.researchgate.net/publication/283792115_Intraocular_pressure_changes_associated_with_tracheal_extubation_Comparison_of_sugammadex_with_conventional_reversal_of_neuromuscular_blockade | - |
dc.identifier.uri | http://earsiv.odu.edu.tr:8080/xmlui/handle/11489/2649 | - |
dc.description.abstract | Objective: To compare the effects of neostigmine/atropine combination and sugammadex on intraocular pressure during tracheal extubation period. Methods: The single-blind prospective randomised controlled study was conducted at Ordu University Research and Training Hospital from August to October 2014, and comprised patients who were randomly assigned to 2 groups according to the agent used for reversal of neuromuscular blockade. Group N received 0.05mgkg-1 neostigmine and 0.02 mgkg-1 atropine and the patients in Group S received 2mgkg-1 sugammadex intravenously. Heart rate, mean arterial pressure and intraocular pressure were measured at baseline, before the induction (T1), after the application of reversal agent (T2), and 1 (T3), 3 (T4), 5 (T5) and 10 (T6) minutes after the extubation. SPSS 16 was used for statistical analysis. Results: There were 36 patients in the study; 18(50%) in each group. There was no significant difference between the groups in terms of age, gender and bodymass index (p>0.05 each). Intraocular pressure was significantly higher when the baseline level was compared with all measurement intervals in Group N (p<0.05 each). In Group S, it showed no significant difference at T2 (p>0.05) whereas it was significantly higher at all other measurement intervals (p<0.05 each). Intergroup comparisons showed statistically significant difference in heart rate and mean arterial pressure levels at T2 interval which were higher in Group N (p<0.01). Intraocular pressure levels at T2 and T3 intervals were significantly higher in Group N (p<0.01). Conclusions: Lower end-extubation intraocular pressure levels were obtained when sugammadex was used as a neuromuscular block reversal agent in comparison with neostigmine-atropine combination. Sugammadex may be a better option for the reversal of neuromuscular blockade and intraocular pressure increase should be avoided in patients with glaucoma or penetrating eye injury. | en_US |
dc.language.iso | eng | en_US |
dc.publisher | PAKISTAN MEDICAL ASSOCPMA HOUSE, AGA KHAN III RD, KARACHI 00000, PAKISTAN | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | LARYNGEAL MASK AIRWAYHEMODYNAMIC-RESPONSESSYSTEMIC ATROPINEANESTHESIAPROPOFOLDEXMEDETOMIDINEINTUBATIONSURGERYEYE | en_US |
dc.subject | NeostigmineAnaestheticsIntraocular pressureSugammadex | en_US |
dc.title | Intraocular pressure changes associated with tracheal extubation: Comparison of sugammadex with conventional reversal of neuromuscular blockade | en_US |
dc.type | article | en_US |
dc.relation.journal | 65 | en_US |
dc.contributor.department | Ordu Üniversitesi | en_US |
dc.contributor.authorID | 0000-0002-2227-194X | en_US |
dc.contributor.authorID | 0000-0003-2093-9229 | en_US |
dc.contributor.authorID | 0000-0003-3020-1586 | en_US |
dc.identifier.volume | 11 | en_US |
dc.identifier.issue | 1219 | en_US |
dc.identifier.startpage | 1225 | en_US |
Appears in Collections: | Cerrahi Tıp Bilimleri |
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.