Please use this identifier to cite or link to this item: http://earsiv.odu.edu.tr:8080/xmlui/handle/11489/2590
Full metadata record
DC FieldValueLanguage
dc.contributor.authorBeni, Valerio-
dc.contributor.authorGolabi, Mohsen-
dc.contributor.authorJager, Edwin W. H.-
dc.contributor.authorKuralay, Filiz-
dc.contributor.authorTurner, Anthony P. F.-
dc.date.accessioned2022-08-17T06:49:46Z-
dc.date.available2022-08-17T06:49:46Z-
dc.date.issued2017-
dc.identifier.urihttp://doi.org/10.1016/j.bios.2016.09.088-
dc.identifier.urihttp://earsiv.odu.edu.tr:8080/xmlui/handle/11489/2590-
dc.description.abstractBiosensors can deliver the rapid bacterial detection that is needed in many fields including food safety, clinical diagnostics, biosafety and biosecurity. Whole-cell imprinted polymers have the potential to be applied as recognition elements in biosensors for selective bacterial detection. In this paper, we report on the use of 3-minophenylboronic acid (3-APBA) for the electrochemical fabrication of a cell-imprinted polymer (CIP). The use of a monomer bearing a boronic acid group, with its ability to specifically interact with cis-diol, allowed the formation of a polymeric network presenting both morphological and chemical recognition abilities. A particularly beneficial feature of the proposed approach is the reversibility of the cis-diol-boronic group complex, which facilitates easy release of the captured bacterial cells and subsequent regeneration of the CIP. Staphylococcus epidermidis was used as the model target bacteria for the CIP and electrochemical impedance spectroscopy (EIS) was explored for the label-free detection of the target bacteria. The modified electrodes showed a linear response over the range of 103-107 cfu/mL. A selectivity study also showed that the CIP could discriminate its target from non-target bacteria having similar shape. The CIPs had high affinity and specificity for bacterial detection and provided a switchable interface for easy removal of bacterial cell.en_US
dc.language.isoengen_US
dc.publisherELSEVIER ADVANCED TECHNOLOGY, OXFORD FULFILLMENT CENTRE THE BOULEVARD, LANGFORD LANE, KIDLINGTON, OXFORD OX5 1GB, OXON, ENGLANDen_US
dc.relation.isversionof10.1016/j.bios.2016.09.088en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subject3-Aminophenylboronic acid; Whole-cell imprinted polymers; Electrochemical impedance spectroscopy; Label-free detection; Staphylococcus epidermidisen_US
dc.subjectPHENYLBORONIC ACID; LABEL-FREE; 3-AMINOPHENYLBORONIC ACID; IMPEDIMETRIC BIOSENSOR; SALMONELLA-TYPHIMURIUM; SELECTIVE DETECTION; PATHOGEN DETECTION; SACCHARIDE SENSOR; POLYPYRROLE FILMS; BORONIC ACIDen_US
dc.titleElectrochemical bacterial detection using poly(3-aminophenylboronic acid)-based imprinted polymeren_US
dc.typearticleen_US
dc.relation.journalBIOSENSORS & BIOELECTRONICSen_US
dc.contributor.departmentOrdu Üniversitesien_US
dc.contributor.authorID0000-0001-6889-0351en_US
dc.contributor.authorID0000-0002-2071-7768en_US
dc.contributor.authorID0000-0002-4332-1993en_US
dc.contributor.authorID0000-0003-0356-9692en_US
dc.identifier.volume93en_US
dc.identifier.startpage87en_US
dc.identifier.endpage93en_US
Appears in Collections:Kimya

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.