Please use this identifier to cite or link to this item:
http://earsiv.odu.edu.tr:8080/xmlui/handle/11489/2310
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Albayrak, Levent | - |
dc.contributor.author | Caltekin, Ibrahim | - |
dc.contributor.author | Demir, Bilgehan | - |
dc.contributor.author | Gokcen, Emre | - |
dc.contributor.author | Korkmaz, Hilal | - |
dc.contributor.author | Savrun, Atakan | - |
dc.contributor.author | Savrun, Seyda Tuba | - |
dc.contributor.author | Yildirim, Gokhan | - |
dc.date.accessioned | 2022-08-17T05:31:14Z | - |
dc.date.available | 2022-08-17T05:31:14Z | - |
dc.date.issued | 2020 | - |
dc.identifier.uri | http://doi.org/10.4274/eajem.galenos.2020.26122 | - |
dc.identifier.uri | http://earsiv.odu.edu.tr:8080/xmlui/handle/11489/2310 | - |
dc.description.abstract | Aim: Among cardiovascular diseases, pulmonary embolism (PE) is a serious emergency with high mortality. Right ventricular dysfunction due to an excessive increase in pulmonary artery pressure is considered a major cause of death in vigorous PE. We aimed to assess the predictive value of computed tomographic pulmonary angiography (CTPA)-based morphometric measurements of right heart function in the diagnosis of PE. Materials and Methods: This is a retrospective, case-controlled study. A total of 198 cases were included in the study during the study phase. CTPA results of 102 patients with PE were recorded, and the patients were grouped according to clot localisation. The diameters of the inferior vena cava (IVCA), aorta, pulmonary artery and right and left ventricles were assessed. Results: IVCA area/aortic area significantly predicted embolism in the main pulmonary artery [area under the curve (AUC)=0.957, p<0.001]. The optimal cut-off value was 1.22 with 88% sensitivity and 90% specificity. IVCA diameter/aortic diameter significantly predicted embolism in the main pulmonary artery (AUC=0.955, p<0.001). The optimal cut-off value was 1.1 with 89% sensitivity and 88% specificity. Conclusion: Our study illustrated a remarkable association between the existence and dispersion of PE and morphometric changes in IVCA and aortic ratio parameters measured using CTPA. | en_US |
dc.language.iso | eng | en_US |
dc.publisher | EMERGENCY MEDICINE PHYSICIANS ASSOC TURKEY, YUKARI AYRANCI GLERYUZ SK NO 26-19, ANKARA, CANKAYA 06550, TURKEY | en_US |
dc.relation.isversionof | 10.4274/eajem.galenos.2020.26122 | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Pulmonary embolism; inferior vena cava diameter; aortic diameter | en_US |
dc.subject | Pulmonary embolism; inferior vena cava diameter; aortic diameter | en_US |
dc.title | Evaluation of Inferior Vena Cava/Abdominal Aorta Diameter Index in Pulmonary Embolism | en_US |
dc.type | article | en_US |
dc.relation.journal | EURASIAN JOURNAL OF EMERGENCY MEDICINE | en_US |
dc.contributor.department | Ordu Üniversitesi | en_US |
dc.contributor.authorID | 0000-0001-7468-4159 | en_US |
dc.contributor.authorID | 0000-0002-9097-1024 | en_US |
dc.identifier.volume | 19 | en_US |
dc.identifier.issue | 2 | en_US |
dc.identifier.startpage | 82 | en_US |
dc.identifier.endpage | 88 | en_US |
Appears in Collections: | Dahili Tıp Bilimleri |
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.