dc.description.abstract | This work is concerned with an experimental design for generating power from thermoelectric generator (TEG) and linear Fresnel lens collector with one-axis solar tracking system. Main purpose of this experimental design is to measure the performance of the TEG with linear Fresnel lens collector. This work also aims to create a mathematical model by using adaptive neuro fuzzy inference system (ANFIS) model so that the electrical production estimates of the constructed system can be made for a given data set. For this reason, two individual systems, selective surface adapted for achieving medium temperature scale and nonselective surface for low temperatures, were constructed. There are two different coolant systems, which are passive and active, to create effective open circuit voltage values. Experimental results show that the maximum open circuit voltages were obtained as 0.442 V and 1.413 V for experimental system with selective surface adapted, as 0.341 V and 0.942 V with nonselective surface adapted when the received radiated power on Fresnel lens was measured nearly 625 W/m2 on average in the noon time. Experimental values were collected for the selective surface adapted system on 11th and 12th of September, 2017 and for nonselective surface on 13th of September, 2017, respectively, in Samsun/Turkey with location 41 degrees 14'N and 36 degrees 26'E. The collected data such as solar irradiation, wind speed, ambiance temperature, and open circuit voltage were used for (ANFIS) modeling. Obtained result shows that experimental calculations and modeling are consistent with each other. | en_US |
dc.language.iso | eng | en_US |
dc.publisher | ASME, TWO PARK AVE, NEW YORK, NY 10016-5990 USA | en_US |
dc.relation.isversionof | 10.1115/1.4039777 | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | POWER-GENERATION; HEAT-RECOVERY; PERFORMANCE; OPTIMIZATION; DESIGN; COLLECTOR; ENERGY | en_US |
dc.title | Experimental and Modeling Study on Solar System Using Linear Fresnel Lens and Thermoelectric Module | en_US |
dc.type | article | en_US |
dc.relation.journal | JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME | en_US |
dc.contributor.department | Ordu Üniversitesi | en_US |
dc.identifier.volume | 140 | en_US |
dc.identifier.issue | 6 | en_US |
Appears in Collections: | Deniz Bilimleri ve Teknolojisi |
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.