Please use this identifier to cite or link to this item: http://earsiv.odu.edu.tr:8080/xmlui/handle/11489/1704
Full metadata record
DC FieldValueLanguage
dc.contributor.authorDede, Dogu O.-
dc.contributor.authorKucukekenci, Ahmet S.-
dc.contributor.authorKurt, Murat-
dc.date.accessioned2022-08-16T06:09:07Z-
dc.date.available2022-08-16T06:09:07Z-
dc.date.issued2018-
dc.identifier.urihttp://doi.org/10.23736/S0026-4970.18.04164-X-
dc.identifier.urihttp://earsiv.odu.edu.tr:8080/xmlui/handle/11489/1704-
dc.description.abstractBACKGROUND: This study investigated the effect of resin cement shade on the final color of computer aided design/computer aided manufacture (CAD/CAM) restorations. METHODS: Thirty CAD/CAM block specimens were fabricated (14x12x1.5 mm) by cutting blocks (Vita Mark II [VM], Vita Enamic [VE], and Lava Ultimate [LU]). Forty cement specimens were prepared (14x12x0.2 mm) using resin cement (RelyX Ultimate Tr, A(1), A(3)O, Bl). Color measurements of CAD/CAM specimens were made without (control) and with each/shade of resin cement (test) with a spectrophotometer. Color differences (Delta E-00) between the control and test groups were calculated and analyzed by 2-way ANOVA and subsequent pairwise testing. Comparisons were performed by using Tukey's multiple comparison tests (alpha=0.05). RESULTS: Both cement shade and interaction between cement shade CAD/CAM block type parameters were significant on color differences (P<0.05). A(3)O cement resulted in a clinically unacceptable color differences (Delta E-00>2.25) for each tested CAD/CAM blocks. Delta E-00 values of VM_A(1) and VE_A(1) groups were also higher than clinically unacceptable level (Delta E-00>2.25). Delta E-00 value of VE_Tr was lower than visually perceptible level (Delta E-00 <= 1.30). There was no statistically significant difference found between the Delta E-00 values of CAD/CAM blocks in the same shade of cement groups (P>0.05). CONCLUSIONS: Tested CAD/CAM blocks were similarly affected by the cement shade and thus may have similar optical features.en_US
dc.language.isoengen_US
dc.publisherEDIZIONI MINERVA MEDICA, CORSO BRAMANTE 83-85 INT JOURNALS DEPT., 10126 TURIN, ITALYen_US
dc.relation.isversionof10.23736/S0026-4970.18.04164-Xen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectPermanent dental restoration; Resin cements; Organically modified ceramicsen_US
dc.titleResin cements effect on the final color of novel monolithic CAD/CAM restorationsen_US
dc.typearticleen_US
dc.relation.journalMINERVA STOMATOLOGICAen_US
dc.contributor.departmentOrdu Üniversitesien_US
dc.contributor.authorID0000-0001-6628-0939en_US
dc.contributor.authorID0000-0003-1021-5702en_US
dc.identifier.volume67en_US
dc.identifier.issue5en_US
dc.identifier.startpage202en_US
dc.identifier.endpage209en_US
Appears in Collections:Protetik Diş Tedavisi

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.