DC Field | Value | Language |
---|---|---|
dc.contributor.author | Dede, Dogu O. | - |
dc.contributor.author | Kucukekenci, Ahmet S. | - |
dc.contributor.author | Kurt, Murat | - |
dc.date.accessioned | 2022-08-16T06:09:07Z | - |
dc.date.available | 2022-08-16T06:09:07Z | - |
dc.date.issued | 2018 | - |
dc.identifier.uri | http://doi.org/10.23736/S0026-4970.18.04164-X | - |
dc.identifier.uri | http://earsiv.odu.edu.tr:8080/xmlui/handle/11489/1704 | - |
dc.description.abstract | BACKGROUND: This study investigated the effect of resin cement shade on the final color of computer aided design/computer aided manufacture (CAD/CAM) restorations. METHODS: Thirty CAD/CAM block specimens were fabricated (14x12x1.5 mm) by cutting blocks (Vita Mark II [VM], Vita Enamic [VE], and Lava Ultimate [LU]). Forty cement specimens were prepared (14x12x0.2 mm) using resin cement (RelyX Ultimate Tr, A(1), A(3)O, Bl). Color measurements of CAD/CAM specimens were made without (control) and with each/shade of resin cement (test) with a spectrophotometer. Color differences (Delta E-00) between the control and test groups were calculated and analyzed by 2-way ANOVA and subsequent pairwise testing. Comparisons were performed by using Tukey's multiple comparison tests (alpha=0.05). RESULTS: Both cement shade and interaction between cement shade CAD/CAM block type parameters were significant on color differences (P<0.05). A(3)O cement resulted in a clinically unacceptable color differences (Delta E-00>2.25) for each tested CAD/CAM blocks. Delta E-00 values of VM_A(1) and VE_A(1) groups were also higher than clinically unacceptable level (Delta E-00>2.25). Delta E-00 value of VE_Tr was lower than visually perceptible level (Delta E-00 <= 1.30). There was no statistically significant difference found between the Delta E-00 values of CAD/CAM blocks in the same shade of cement groups (P>0.05). CONCLUSIONS: Tested CAD/CAM blocks were similarly affected by the cement shade and thus may have similar optical features. | en_US |
dc.language.iso | eng | en_US |
dc.publisher | EDIZIONI MINERVA MEDICA, CORSO BRAMANTE 83-85 INT JOURNALS DEPT., 10126 TURIN, ITALY | en_US |
dc.relation.isversionof | 10.23736/S0026-4970.18.04164-X | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Permanent dental restoration; Resin cements; Organically modified ceramics | en_US |
dc.title | Resin cements effect on the final color of novel monolithic CAD/CAM restorations | en_US |
dc.type | article | en_US |
dc.relation.journal | MINERVA STOMATOLOGICA | en_US |
dc.contributor.department | Ordu Üniversitesi | en_US |
dc.contributor.authorID | 0000-0001-6628-0939 | en_US |
dc.contributor.authorID | 0000-0003-1021-5702 | en_US |
dc.identifier.volume | 67 | en_US |
dc.identifier.issue | 5 | en_US |
dc.identifier.startpage | 202 | en_US |
dc.identifier.endpage | 209 | en_US |