Please use this identifier to cite or link to this item: http://earsiv.odu.edu.tr:8080/xmlui/handle/11489/1589
Title: Apical Extrusion of Debris and Irrigant Using XP-Endo Finisher, EndoActivator, Passive Ultrasonic Irrigation or Syringe Irrigation
Authors: Keskin, Cangul
Sariyilmaz, Evren
Ordu Üniversitesi
0000-0003-1711-7056
Keywords: XP-Endo Finisher; passive ultrasonic irrigation; sonic irrigation; apical extrusion
Issue Date: 2018
Publisher: GALENOS YAYINCILIK, ERKAN MOR, MOLLA GURANI CAD 21-1, FINDIKZADE, ISTANBUL 34093, TURKEY
Abstract: Objective: Extrusion of irrigant and debris into the periapical tissues is a potential risk for flare-ups during root canal treatment. The aim of this study was to evaluate the apically extruded debris and sodium hypochlorite during XP-Endo Finisher (XP-Endo) file use and compare with final irrigation techniques. The tested null hypothesis in this study was that there was no difference among the irrigation techniques. Materials and Methods: An agar gel model was prepared for 80 extracted single rooted human mandibular premolar teeth, which were prepared up to the apical size of #40. The samples were divided into four groups according to the final irrigation regime: conventional syringe irrigation, XP-Endo, passive ultrasonic irrigation (PUI), and EndoActivator (EA). The test apparatus was weighed before and after the experiment, and the amount of apically extruded debris and irrigant was calculated. Results: There was minimal irrigant and debris extrusion in all groups. No significant difference among the tested groups was detected (p>0.05). Conclusion: Using the PUI, XP-Endo file, or EA according to the manufacturers' instruction does not increase the extrusion risk. Keywords
URI: http://doi.org/10.4274/meandros.24008
http://earsiv.odu.edu.tr:8080/xmlui/handle/11489/1589
Appears in Collections:Endodonti

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.