Please use this identifier to cite or link to this item: http://earsiv.odu.edu.tr:8080/xmlui/handle/11489/1539
Full metadata record
DC FieldValueLanguage
dc.contributor.authorAyranci, F.-
dc.contributor.authorDayi, E.-
dc.contributor.authorGhahramanzadehasl, H.-
dc.contributor.authorKaragol, S.-
dc.contributor.authorOmezli, M. M.-
dc.contributor.authorPolat, M. E.-
dc.date.accessioned2022-08-16T05:22:18Z-
dc.date.available2022-08-16T05:22:18Z-
dc.date.issued2017-
dc.identifier.urihttp://doi.org/10.4103/1119-3077.187319-
dc.identifier.urihttp://earsiv.odu.edu.tr:8080/xmlui/handle/11489/1539-
dc.description.abstractObjectives: The purpose of this experimental study was to compare the biomechanical behaviors of two different types of osteosynthesis that are used in the treatment of mandibular angle fractures. Materials and Methods: Twenty synthetic polyurethane human mandible replicas, with medullar and cortical portions, were used in this study. These polyurethane hemimandibles were randomly divided into two groups (n = 10). The transbuccal group (Group A) was fixed with 7 mm long self-tapping 2.0 mm titanium screws at 85 degrees to the reference line and the transoral group (Group B) was fixed with the same screws at 15 degrees to the reference line. All testings were performed on a servo-hydraulic testing machine. The data were transmitted directly from the load cell to a computer, which showed the emergent results of the material characteristics under resisted forces as a graphic containing force and displacement. The peak point loading and displacement for each subject were measured. Results: The comparison between the groups was analyzed with an independent-samples t-test, and P < 0.05 was considered to be significant. The results show that there were no significant differences between the groups for the peak loads and displacement values at the peak loads. Conclusion: The results of this experimental study demonstrated that there were no significant differences between the transbuccal and transoral methods in terms of fixation stability. In other words, the screw position and angle seemed to no have influence on the fixation stability in single miniplate treatments of a mandibular angle fracture.en_US
dc.language.isoengen_US
dc.publisherMEDKNOW PUBLICATIONS & MEDIA PVT LTD, B-9, KANARA BUSINESS CENTRE, OFF LINK RD, GHAKTOPAR-E, MUMBAI, 400075, INDIAen_US
dc.relation.isversionof10.4103/1119-3077.187319en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectMiniplate fixation; stability; transbuccalen_US
dc.subjectMINIPLATE; OSTEOSYNTHESIS; TITANIUM; CONDYLE; TRIAL; SCREWen_US
dc.titleBiomechanical Comparison of Transoral and Transbuccal Lateral Cortical Plate Fixation for the Management of Mandibular Angle Fracturesen_US
dc.typearticleen_US
dc.relation.journalNIGERIAN JOURNAL OF CLINICAL PRACTICEen_US
dc.contributor.departmentOrdu Üniversitesien_US
dc.contributor.authorID0000-0001-7126-5696en_US
dc.contributor.authorID0000-0002-5750-1143en_US
dc.contributor.authorID0000-0002-6606-6593en_US
dc.identifier.volume20en_US
dc.identifier.issue11en_US
dc.identifier.startpage1434en_US
dc.identifier.endpage1438en_US
Appears in Collections:Ağız, Diş ve Çene Cerrahisi

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.