Please use this identifier to cite or link to this item: http://earsiv.odu.edu.tr:8080/xmlui/handle/11489/1535
Full metadata record
DC FieldValueLanguage
dc.contributor.authorAyranci, Ferhat-
dc.contributor.authorOmezli, M. Melih-
dc.contributor.authorSivrikaya, Efe Can-
dc.date.accessioned2022-08-16T05:21:24Z-
dc.date.available2022-08-16T05:21:24Z-
dc.date.issued2017-
dc.identifier.urihttp://doi.org/10.1080/13102818.2017.1376597-
dc.identifier.urihttps://www.tandfonline.com/doi/full/10.1080/13102818.2017.1376597-
dc.identifier.urihttp://earsiv.odu.edu.tr:8080/xmlui/handle/11489/1535-
dc.description.abstractThe aim of this study was to compare the stresses on cylindrical and conical dental implants under heavy bruxing forces, in D1 and D4 bone densities, using three-dimensional finite element analysis (FEA). Eight different stress models were created according to implant design (cylindrical or conical), bone density (D1 or D4) and load (1000N, vertical or oblique). The von Mises stresses for each model were compared using FEA. The obtained results showed that D1 bone density and vertical force were associated with the least stress on the implant. Bone density was more important than implant design in stress formation. The results from the two implant types were very similar. The von Mises stress values were greater in the neck region of the implant. We suggest that the implant region should be considered firstly for less stress on the implant.en_US
dc.language.isoengen_US
dc.publisherTAYLOR & FRANCIS LTD, 2-4 PARK SQUARE, MILTON PARK, ABINGDON OR14 4RN, OXON, ENGLANDen_US
dc.relation.isversionof10.1080/13102818.2017.1376597en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectDensity; dental implant; design; finite element analysisen_US
dc.subjectFINITE-ELEMENT-ANALYSIS; DENTAL IMPLANTS; FAILURES; MULTICENTER; MAXILLARY; SURVIVALen_US
dc.titleIs bone density or implant design more important in implant stress formation in patients with bruxism?en_US
dc.typearticleen_US
dc.relation.journalBIOTECHNOLOGY & BIOTECHNOLOGICAL EQUIPMENTen_US
dc.contributor.departmentOrdu Üniversitesien_US
dc.contributor.authorID0000-0001-6798-7610en_US
dc.identifier.volume31en_US
dc.identifier.issue6en_US
dc.identifier.startpage1221en_US
dc.identifier.endpage1225en_US
Appears in Collections:Ağız, Diş ve Çene Cerrahisi

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.