Please use this identifier to cite or link to this item: http://earsiv.odu.edu.tr:8080/xmlui/handle/11489/1528
Full metadata record
DC FieldValueLanguage
dc.contributor.authorDayi, E.-
dc.contributor.authorOmezli, M. M.-
dc.contributor.authorPolat, M. E.-
dc.contributor.authorTorul, D.-
dc.date.accessioned2022-08-16T05:19:41Z-
dc.date.available2022-08-16T05:19:41Z-
dc.date.issued2015-
dc.identifier.urihttp://doi.org/10.4103/1119-3077.158946-
dc.identifier.urihttp://earsiv.odu.edu.tr:8080/xmlui/handle/11489/1528-
dc.description.abstractBackground and Aims: The aim of this study was to compare the biomechanical stability of poly-L-lactic acid and titanium screws in the fixation of intracapsular condylar fractures, in 10 polyurethane hemimandibles. Materials and Methods: Artificial intracapsular fractures were created with a steel disk and electronic micromotor. The first group was fixed with 15 mm long self-tapping 2.0 mm system titanium screws and the second group was fixed with 15 mm long 2.4 mm bioresorbable screws. Linear loads of 25, 50, 75, 100 N was applied in anteroposterior direction to the hemimandibles and the data were transmitted directly from the load cell to a computer that shows emergent results of material characteristics under same forces as a graphic containing force and displacement. Results: The results show that there were no significant differences between the two methods, with 25 N of loading. (P > 0,05) The difference became significant with a higher value of loading. Conclusion: The results suggest that treatment with a single resorbable screw is not functionally stable as a single titanium screw.en_US
dc.language.isoengen_US
dc.publisherWOLTERS KLUWER MEDKNOW PUBLICATIONSWOLTERS KLUWER INDIA PVT LTD, A-202, 2ND FLR, QUBE, C T S NO 1498A-2 VILLAGE MAROL, ANDHERI EAST, MUMBAI 400059, INDIAen_US
dc.relation.isversionof10.4103/1119-3077.158946en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectIntracapsular condylar fracturesosteosynthesisscrew fixationen_US
dc.subjectMANDIBULAR CONDYLERESORBABLE PINSDIACAPITULAR FRACTURESIN-VITROSHEEPHEADRESISTANCEREDUCTIONPLATESen_US
dc.titleBiomechanical comparison of osteosynthesis with poly-L-lactic acid and titanium screw in intracapsular condylar fracture fixation: An experimental studyen_US
dc.typearticleen_US
dc.relation.journalNIGERIAN JOURNAL OF CLINICAL PRACTICEen_US
dc.contributor.departmentOrdu Üniversitesien_US
dc.contributor.authorID0000-0002-6606-6593en_US
dc.contributor.authorID0000-0003-2323-606Xen_US
dc.identifier.volume18en_US
dc.identifier.issue5en_US
dc.identifier.startpage589en_US
dc.identifier.endpage593en_US
Appears in Collections:Ağız, Diş ve Çene Cerrahisi

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.