Please use this identifier to cite or link to this item:
http://earsiv.odu.edu.tr:8080/xmlui/handle/11489/1528
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Dayi, E. | - |
dc.contributor.author | Omezli, M. M. | - |
dc.contributor.author | Polat, M. E. | - |
dc.contributor.author | Torul, D. | - |
dc.date.accessioned | 2022-08-16T05:19:41Z | - |
dc.date.available | 2022-08-16T05:19:41Z | - |
dc.date.issued | 2015 | - |
dc.identifier.uri | http://doi.org/10.4103/1119-3077.158946 | - |
dc.identifier.uri | http://earsiv.odu.edu.tr:8080/xmlui/handle/11489/1528 | - |
dc.description.abstract | Background and Aims: The aim of this study was to compare the biomechanical stability of poly-L-lactic acid and titanium screws in the fixation of intracapsular condylar fractures, in 10 polyurethane hemimandibles. Materials and Methods: Artificial intracapsular fractures were created with a steel disk and electronic micromotor. The first group was fixed with 15 mm long self-tapping 2.0 mm system titanium screws and the second group was fixed with 15 mm long 2.4 mm bioresorbable screws. Linear loads of 25, 50, 75, 100 N was applied in anteroposterior direction to the hemimandibles and the data were transmitted directly from the load cell to a computer that shows emergent results of material characteristics under same forces as a graphic containing force and displacement. Results: The results show that there were no significant differences between the two methods, with 25 N of loading. (P > 0,05) The difference became significant with a higher value of loading. Conclusion: The results suggest that treatment with a single resorbable screw is not functionally stable as a single titanium screw. | en_US |
dc.language.iso | eng | en_US |
dc.publisher | WOLTERS KLUWER MEDKNOW PUBLICATIONSWOLTERS KLUWER INDIA PVT LTD, A-202, 2ND FLR, QUBE, C T S NO 1498A-2 VILLAGE MAROL, ANDHERI EAST, MUMBAI 400059, INDIA | en_US |
dc.relation.isversionof | 10.4103/1119-3077.158946 | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Intracapsular condylar fracturesosteosynthesisscrew fixation | en_US |
dc.subject | MANDIBULAR CONDYLERESORBABLE PINSDIACAPITULAR FRACTURESIN-VITROSHEEPHEADRESISTANCEREDUCTIONPLATES | en_US |
dc.title | Biomechanical comparison of osteosynthesis with poly-L-lactic acid and titanium screw in intracapsular condylar fracture fixation: An experimental study | en_US |
dc.type | article | en_US |
dc.relation.journal | NIGERIAN JOURNAL OF CLINICAL PRACTICE | en_US |
dc.contributor.department | Ordu Üniversitesi | en_US |
dc.contributor.authorID | 0000-0002-6606-6593 | en_US |
dc.contributor.authorID | 0000-0003-2323-606X | en_US |
dc.identifier.volume | 18 | en_US |
dc.identifier.issue | 5 | en_US |
dc.identifier.startpage | 589 | en_US |
dc.identifier.endpage | 593 | en_US |
Appears in Collections: | Ağız, Diş ve Çene Cerrahisi |
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.