dc.contributor.author |
Yilmaz, Burak |
|
dc.contributor.author |
Dede, Dogu Omur |
|
dc.contributor.author |
Diker, Emre |
|
dc.contributor.author |
Fonseca, Manrique |
|
dc.contributor.author |
Johnston, William Michael |
|
dc.contributor.author |
Kucukekenci, Ahmet Serkan |
|
dc.date.accessioned |
2024-03-26T06:56:26Z |
|
dc.date.available |
2024-03-26T06:56:26Z |
|
dc.date.issued |
2023 |
|
dc.identifier.citation |
Yilmaz, B., Dede, DÖ., Diker, E., Fonseca, M., Johnston, WM., Küçükekenci, AS. (2023). Effect of cross-polarization filters on the trueness of colors obtained with a single-lens reflex camera, macro lens, and a ring flash. J. Esthet. Restor. Dent.. https://doi.org/10.1111/jerd.13053 |
en_US |
dc.identifier.issn |
1496-4155 |
|
dc.identifier.issn |
1708-8240 |
|
dc.identifier.uri |
http://dx.doi.org/10.1111/jerd.13053 |
|
dc.identifier.uri |
https://www.webofscience.com/wos/woscc/full-record/WOS:000970144200001 |
|
dc.identifier.uri |
http://earsiv.odu.edu.tr:8080/xmlui/handle/11489/5262 |
|
dc.description |
WoS Categories: Dentistry, Oral Surgery & Medicine |
en_US |
dc.description |
Web of Science Index: Science Citation Index Expanded (SCI-EXPANDED) |
en_US |
dc.description |
Research Areas: Dentistry, Oral Surgery & Medicine |
en_US |
dc.description.abstract |
ObjectiveTo investigate the effect of cross-polarization filters on the colors of shade tabs obtained with a digital single-lens reflex (DSLR) camera, macrolens, and a ring flash. Materials and MethodsDigital images of four shade tables (1M1, 3L2.5, 3R2.5, and 5M3) from the VITA Toothguide 3D-Master shade guide were taken using a DSLR camera, 100 mm macrolens, and ring flash with two different cross-polarizing filters (Polar_eyes and Filtropolar), and without (Nonpolarizer; n = 7). The CIE L*a*b* color coordinates of digital images were calculated and remeasured with a spectroradiometer (SR). The color differences (Delta E-00) between the SR and digital images were calculated and analyzed with the two-way analysis of variance (ANOVA) and Tukey HSD test (alpha = 0.05). Results Delta E-00 values of all test groups were higher than the clinically acceptable threshold ( increment E-00 > 1.80). While the increment E-00 values of Filtropolar (6.19 +/- 0.44) and Polar_eyes (7.82 +/- 0.23) groups were significantly higher than the Nonpolarizer (4.69 +/- 0.32) for the 1M1 shade tab, increment E-00 value of Polar_eyes (6.23 +/- 0.34) was significantly lower than Nonpolarizer (10.71 +/- 0.48) group for 5M3 shade tab (p < 0.05). ConclusionThe color-matching results of tested digital photography techniques with and without cross-polarization were unacceptable, compared to a spectroradiometer. While digital photography with Polar_eyes cross-polarizing filter has closer results to the reference device for the low-in-value shade table (5M3), for the high-in-value shade table (1M1), improved results were obtained without a cross-polarizing filter. Clinical SignificanceThe cross-polarization filters are increasingly used in dentistry for tooth color communication with digital photography techniques. However, the digital photography techniques with-without cross-polarization filterers should be improved to obtain clinically acceptable color-matching results. |
en_US |
dc.language.iso |
eng |
en_US |
dc.publisher |
WILEY-HOBOKEN |
en_US |
dc.relation.isversionof |
10.1111/jerd.13053 |
en_US |
dc.rights |
info:eu-repo/semantics/openAccess |
en_US |
dc.subject |
color difference, color matching, cross-polarizing filter, digital image, spectroradiometer |
en_US |
dc.subject |
DENTAL PHOTOGRAPHY, SHADE, DIFFERENCE |
en_US |
dc.title |
Effect of cross-polarization filters on the trueness of colors obtained with a single-lens reflex camera, macro lens, and a ring flash |
en_US |
dc.type |
article |
en_US |
dc.relation.journal |
JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY |
en_US |
dc.contributor.department |
Ordu Üniversitesi |
en_US |
dc.contributor.authorID |
0000-0003-1021-5702 |
en_US |
dc.contributor.authorID |
0000-0003-2356-0142 |
en_US |
dc.contributor.authorID |
0000-0003-4267-0515 |
en_US |