DSpace Repository

Microleakage of 4 post-luting cements evaluated by the computerized fluid filtration method

Show simple item record

dc.contributor.author Ceyhanli, Kadir T.
dc.contributor.author Orucoglu, Hasan
dc.contributor.author Erdilek, Necdet
dc.contributor.author Turkun, Murat
dc.contributor.author Akdag, Mustafa S.
dc.date.accessioned 2024-03-26T06:55:33Z
dc.date.available 2024-03-26T06:55:33Z
dc.date.issued 2015
dc.identifier.citation Ceyhanli, KT., Orucoglu, H., Erdilek, N., Turkun, M., Akdag, MS. (2015). Microleakage of 4 post-luting cements evaluated by the computerized fluid filtration method. Int. J. Artif. Organs, 38(12), 646-650. https://doi.org/10.5301/ijao.5000459 en_US
dc.identifier.issn 0391-3988
dc.identifier.issn 1724-6040
dc.identifier.uri http://dx.doi.org/10.5301/ijao.5000459
dc.identifier.uri https://www.webofscience.com/wos/woscc/full-record/WOS:000371790500004
dc.identifier.uri http://earsiv.odu.edu.tr:8080/xmlui/handle/11489/5253
dc.description WoS Categories: Engineering, Biomedical; Transplantation en_US
dc.description Web of Science Index: Science Citation Index Expanded (SCI-EXPANDED) en_US
dc.description Research Areas: Engineering; Transplantation en_US
dc.description.abstract Purpose: The aim of this study was to evaluate the microleakage of 4 fiber post-luting systems using the computerized fluid filtration method. Methods: 60 extracted human mandibular permanent premolar teeth were used for the study. The teeth were instrumented with Hedstroem files up to size 60, post spaces were prepared and then Unicore fiber posts were cemented using 4 luting systems. Group1: Duolink, Group 2: Resinomer, Group 3: Fuji Plus, Group 4: Multilink Sprint, Group 5: Positive Control, and Group 6: Negative Control. The samples were stored in distilled water for 2 weeks and then microleakage was evaluated. Data were analyzed with 1 way-ANOVA and Dunett T3 tests (P<.05). Groups 2 and 3 significantly exhibited higher microleakage values than groups 1 and 4 (P<.05). Results: Resin cements used with total etch-bonding systems demonstrated lower microleakage values than the other cements. Conclusions: Reduction of steps in dentin conditioning of resin luting cements may have a promoting effect on microleakage. en_US
dc.language.iso eng en_US
dc.publisher SAGE PUBLICATIONS LTD-LONDON en_US
dc.relation.isversionof 10.5301/ijao.5000459 en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.subject Fiber post, Luting cement, Microleakage en_US
dc.subject ENDODONTICALLY TREATED TEETH, MARGINAL GAP FORMATION, FIBER POSTS, APICAL LEAKAGE, BACTERIAL PENETRATION, RESIN COMPOSITE, BOND STRENGTH, ROOT FILLINGS, DENTIN, RETENTION en_US
dc.title Microleakage of 4 post-luting cements evaluated by the computerized fluid filtration method en_US
dc.type article en_US
dc.relation.journal INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS en_US
dc.contributor.department Ordu Üniversitesi en_US
dc.identifier.volume 38 en_US
dc.identifier.issue 12 en_US
dc.identifier.startpage 646 en_US
dc.identifier.endpage 650 en_US


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account