DSpace Repository

ENERGETIC AND EXERGETIC COMPARISON OF AIR TO AIR AND AIR TO WATER HEAT PUMPS ACCORDING TO EVAPORATOR CONDITIONS

Show simple item record

dc.contributor.author Comakli, Kemal
dc.contributor.author UgurCakir
dc.contributor.author Sahin, Erol
dc.contributor.author Kus, Aysegul Cokgez
dc.date.accessioned 2024-03-19T06:54:29Z
dc.date.available 2024-03-19T06:54:29Z
dc.date.issued 2013
dc.identifier.citation Comakli, K., UgurÇakir., Sahin, E., Kus, AÇ. (2013). ENERGETIC AND EXERGETIC COMPARISON OF AIR TO AIR AND AIR TO WATER HEAT PUMPS ACCORDING TO EVAPORATOR CONDITIONS. Int. J. Automot. Mech. Eng, 8, 1108-1120. https://doi.org/10.15282/ijame.8.2013.2.1108-1120 en_US
dc.identifier.issn 2229-8649
dc.identifier.issn 2180-1606
dc.identifier.uri http://dx.doi.org/10.15282/ijame.8.2013.2.1108-1120
dc.identifier.uri https://www.webofscience.com/wos/woscc/full-record/WOS:000434543300002
dc.identifier.uri http://earsiv.odu.edu.tr:8080/xmlui/handle/11489/4750
dc.description WoS Categories: Engineering, Mechanical en_US
dc.description Web of Science Index: Emerging Sources Citation Index (ESCI) en_US
dc.description Research Areas: Engineering en_US
dc.description.abstract This paper presents an experimental energetic and exergetic comparison for a heat pump system that can be run in different modes as air to air and air to water. Components of the heat pump do not change when the running mode changes, except for the condenser. This means that some external and internal effects (like compressor type, pipe lines) that can affect the system performance will be the same for each running mode. The comparison which was made in this study demonstrates which system leads to an efficient conversion and supply of energy and exergy. In the analysis, four balance (mass, energy, entropy and exergy) equations are applied to the system for the two modes. Exergy and energy efficiency values for both systems are given, while exergy destructions in each of the systems are determined and presented. It is seen that the heat pump unit which has the highest COP value is the air to air type (3.45-3.8); second is the air to water type (3.35-3.41). The exergy efficiency of the air to air heat pump (29-32%) is higher than the exergy efficiency of the air to water type heat pump (24.1-25). Ranking of the exergy destruction rates of the two heat pump types from high to low is as follows: air to air and air to water. en_US
dc.description.sponsorship Turkish Scientific and Technological Research Council of Turkey (TUBITAK) [105M030]; Ataturk University, Research Project Foundation [BAP-2005/16] en_US
dc.language.iso eng en_US
dc.publisher UNIV MALAYSIA PAHANG-PAHANG en_US
dc.relation.isversionof 10.15282/ijame.8.2013.2.1108-1120 en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.subject Heat pump, heat pump comparison, exergy, energy saving en_US
dc.title ENERGETIC AND EXERGETIC COMPARISON OF AIR TO AIR AND AIR TO WATER HEAT PUMPS ACCORDING TO EVAPORATOR CONDITIONS en_US
dc.type article en_US
dc.relation.journal INTERNATIONAL JOURNAL OF AUTOMOTIVE AND MECHANICAL ENGINEERING en_US
dc.contributor.department Ordu Üniversitesi en_US
dc.identifier.volume 8 en_US
dc.identifier.startpage 1108 en_US
dc.identifier.endpage 1120 en_US


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account