DSpace Repository

An Electrochemical Acetylcholinesterase Biosensor Based on Fluorene(bisthiophene) Comprising Polymer for Paraoxon Detection

Show simple item record

dc.contributor.author Celik, Huzeyfe
dc.contributor.author Soylemez, Saniye
dc.date.accessioned 2024-03-15T11:08:33Z
dc.date.available 2024-03-15T11:08:33Z
dc.date.issued 2023
dc.identifier.citation Celik, H., Soylemez, S. (2023). An Electrochemical Acetylcholinesterase Biosensor Based on Fluorene(bisthiophene) Comprising Polymer for Paraoxon Detection. Electroanalysis, 35(3). https://doi.org/10.1002/elan.202200271 en_US
dc.identifier.issn 1040-0397
dc.identifier.issn 1521-4109
dc.identifier.uri http://dx.doi.org/10.1002/elan.202200271
dc.identifier.uri https://www.webofscience.com/wos/woscc/full-record/WOS:000849808200001
dc.identifier.uri http://earsiv.odu.edu.tr:8080/xmlui/handle/11489/4398
dc.description WoS Categories: Chemistry, Analytical; Electrochemistry en_US
dc.description Web of Science Index: Science Citation Index Expanded (SCI-EXPANDED) en_US
dc.description Research Areas: Chemistry; Electrochemistry en_US
dc.description.abstract In this study, a novel conductive polymer comprising biosensor based on poly-2,2 '-(9,9-dioctyl-9 h-fluorene-2,7-diyl)bistiophene (Poly(BT)) and acetylcholinesterase (AChE) was reported for the determination of paraoxon. This practical biosensor allowed to catalyze electrochemical oxidation of acetylthiocholine (+0.6 V vs. Ag reference). The detection range for acetylcholine chloride (AThCl) with Poly(BT)/AChE was found to be 0.025-4 mM. In pesticide analysis, wide linear ranges from 0.5 to 1 mu g/L and 1 to 14 mu g/L, and a low detection limit of 0.033 mu g/L were estimated. Under optimum operating conditions, the developed biosensor was used for pesticide detection in milk and tap water samples, effectively. en_US
dc.description.sponsorship Ordu University BAP project [B-2111] en_US
dc.language.iso eng en_US
dc.publisher WILEY-V C H VERLAG GMBH-WEINHEIM en_US
dc.relation.isversionof 10.1002/elan.202200271 en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.subject Electrochemical Biosensor, Conjugated Polymer, Acetylcholinesterase, Enzyme Immobilization, Organophosphorus Pesticides en_US
dc.subject CARBON NANOTUBES, AMPEROMETRIC DETECTION, CONJUGATED POLYMER, PESTICIDES, ORGANOPHOSPHATE, IMMOBILIZATION, NANOPARTICLES, ELECTRODES, SURFACE, WATER en_US
dc.title An Electrochemical Acetylcholinesterase Biosensor Based on Fluorene(bisthiophene) Comprising Polymer for Paraoxon Detection en_US
dc.type article en_US
dc.relation.journal ELECTROANALYSIS en_US
dc.contributor.department Ordu Üniversitesi en_US
dc.contributor.authorID 0000-0002-8955-133X en_US
dc.contributor.authorID 0000-0002-8955-133X en_US
dc.identifier.volume 35 en_US
dc.identifier.issue 3 en_US


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account