DSpace Repository

Evaluation of reused orthodontic mini- implants on stability: An in-vivo study

Show simple item record

dc.contributor.author Ozkan, Serkan
dc.contributor.author Buyuk, Suleyman Kutalmis
dc.contributor.author Gok, Firat
dc.contributor.author Benkli, Yasin Atakan
dc.date.accessioned 2024-03-15T06:53:45Z
dc.date.available 2024-03-15T06:53:45Z
dc.date.issued 2022
dc.identifier.citation Özkan, S., Büyük, SK., Gök, F., Benkli, YA. (2022). Evaluation of reused orthodontic mini- implants on stability: An in-vivo study. Am. J. Orthod. Dentofac. Orthop., 162(5), 689-694. https://doi.org/10.1016/j.ajodo.2021.06.024 en_US
dc.identifier.issn 0889-5406
dc.identifier.issn 1097-6752
dc.identifier.uri http://dx.doi.org/10.1016/j.ajodo.2021.06.024
dc.identifier.uri https://www.webofscience.com/wos/woscc/full-record/WOS:000884789700023
dc.identifier.uri http://earsiv.odu.edu.tr:8080/xmlui/handle/11489/4047
dc.description WoS Categories: Dentistry, Oral Surgery & Medicine en_US
dc.description Web of Science Index: Science Citation Index Expanded (SCI-EXPANDED) en_US
dc.description Research Areas: Dentistry, Oral Surgery & Medicine en_US
dc.description.abstract Introduction: During treatment, some patients may need to change the location of mini-implants (MIs). This study investigated the stability of MIs relocated to another position in the same patient using the periotest and torque device. Methods: Twenty-nine MIs were applied randomly to 1 side of the maxillary region, and torque and periotest values were recorded. The patients were followed-up at 4-week intervals, and periotest measurements were performed at each session. After recording the torque and periotest values in the fourth session, the MIs were removed. After applying the appropriate sterilization procedure, the same MIs were relocated to the contralateral side of the patients' jaw, and distalization was achieved using a similar procedure for the group of as-received MIs. Results: Negative correlations were obtained between the torque meter and periotest data for both MI groups. We observed no significant effect of the MI group on periotest mea-surements (P>0.05). The effect of the MI group on torque values and the interaction effect of the MI group and torque values were not statistically significant (P >0.05). Conclusions: It is possible to achieve similar stability values with as-received and retrieved MIs when appropriate cleaning and sterilization protocols are performed. en_US
dc.description.sponsorship Scientific Research Projects Commission of Ordu University; [AR-1528] en_US
dc.language.iso eng en_US
dc.publisher MOSBY-ELSEVIER-NEW YORK en_US
dc.relation.isversionof 10.1016/j.ajodo.2021.06.024 en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.subject SODIUM-HYPOCHLORITE, PERIOTEST VALUES, ANCHORAGE, TORQUE en_US
dc.title Evaluation of reused orthodontic mini- implants on stability: An in-vivo study en_US
dc.type article en_US
dc.relation.journal AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS en_US
dc.contributor.department Ordu Üniversitesi en_US
dc.identifier.volume 162 en_US
dc.identifier.issue 5 en_US
dc.identifier.startpage 689 en_US
dc.identifier.endpage 694 en_US


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account