Electrochemical Corrosion and Metal Ion Release Protective Efficiency of the Multilayer TaN Coatings on CoCrMo Biomedical Alloy

Show simple item record

dc.contributor.author Aslan, Ali Kemal
dc.contributor.author Bahce, Erkan
dc.contributor.author Guler, Mehmet Sami
dc.date.accessioned 2023-01-06T12:08:16Z
dc.date.available 2023-01-06T12:08:16Z
dc.date.issued 2021
dc.identifier.citation Aslan, AK., Bahce, E., Guler, MS. (2021). Electrochemical Corrosion and Metal Ion Release Protective Efficiency of the Multilayer TaN Coatings on CoCrMo Biomedical Alloy. Materials Science-Medziagotyra, 27(4), 416-424.Doi:10.5755/j02.ms.27695 en_US
dc.identifier.isbn 1392-1320
dc.identifier.isbn 2029-7289
dc.identifier.uri http://dx.doi.org/10.5755/j02.ms.27695
dc.identifier.uri https://www.webofscience.com/wos/woscc/full-record/WOS:000726736600007
dc.identifier.uri http://earsiv.odu.edu.tr:8080/xmlui/handle/11489/3629
dc.description WoS Categories : Materials Science, Multidisciplinary Web of Science Index : Science Citation Index Expanded (SCI-EXPANDED) Research Areas : Materials Science Open Access Designations : gold en_US
dc.description.abstract CoCrMo alloy is widely used in artificial orthopedic joint applications due to its high mechanical properties. But, high levels of the metal ion release from alloy surfaces cause variable toxic and allergic effects on the patient in vivo use. This case restricts the lifetime of the implant and results in the failure of the artificial joint. In order to enhance the corrosion resistance and to decrease the metal ion release, alloy surface was multilayer-coated by closed field unbalanced magnetron system. The protective efficiency of the coatings was determined by potentiodynamic polarization tests and static immersion tests were performed for 45, 60 and 90 days in the simulated body fluid in order to understand the effect of the coatings on the metal ion release. The metal ion concentrations in the simulated body fluids were determined by using inductively coupled plasma mass spectrometry device. The electrochemical corrosion results showed that the multilayer coatings provided 93 % protective efficiency in terms of corrosion resistance. Multilayer coatings decreased the metal ions release levels significantly, especially Co leaking was decreased approximately 52 times compared to uncoated samples. en_US
dc.language.iso eng en_US
dc.publisher KAUNAS UNIV TECH KAUNAS en_US
dc.relation.isversionof 10.5755/j02.ms.27695 en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.subject COATED COCRMO; FILMS; BEHAVIOR; RESISTANCE; SPECIATION; TOXICITY; IMPLANTS; COBALT; WEAR; BODY en_US
dc.subject CoCrMo; biomaterial; multilayer coating; corrosion; metal ion release en_US
dc.title Electrochemical Corrosion and Metal Ion Release Protective Efficiency of the Multilayer TaN Coatings on CoCrMo Biomedical Alloy en_US
dc.type article en_US
dc.relation.journal MATERIALS SCIENCE-MEDZIAGOTYRA en_US
dc.contributor.department Ordu Üniversitesi en_US
dc.identifier.volume 27 en_US
dc.identifier.issue 4 en_US
dc.identifier.startpage 416 en_US
dc.identifier.endpage 424 en_US