DSpace Repository

Monitoring and modelling of long-term radiofrequency electromagnetic field levels

Show simple item record

dc.contributor.author Kurnaz, Cetin
dc.contributor.author Mutlu, Mustafa
dc.date.accessioned 2023-01-06T11:15:56Z
dc.date.available 2023-01-06T11:15:56Z
dc.date.issued 2021
dc.identifier.citation Kurnaz, C., Mutlu, M. (2021). Monitoring and modelling of long-term radiofrequency electromagnetic field levels. Journal of the Faculty of Engineering and Architecture of Gazi University, 36(2), 669-683.Doi:10.17341/gazimmfd.641287 en_US
dc.identifier.isbn 1300-1884
dc.identifier.isbn 1304-4915
dc.identifier.uri http://dx.doi.org/10.17341/gazimmfd.641287
dc.identifier.uri https://www.webofscience.com/wos/woscc/full-record/WOS:000626722500007
dc.identifier.uri http://earsiv.odu.edu.tr:8080/xmlui/handle/11489/3508
dc.description WoS Categories : Engineering, Multidisciplinary Web of Science Index : Science Citation Index Expanded (SCI-EXPANDED) Research Areas : Engineering Open Access Designations : gold, Green Submitted en_US
dc.description.abstract In this study, in order to determine the radiofrequency electromagnetic field (RF-EMF) level exposed in the home environment and to model its change, 24-hour RF-EMF measurements were performed in the frequency range of 100 kHz to 3 GHz. In measurements, the highest RF-EMF value was recorded as 17.31 V/m, which is below the limit values determined by ICNIRP and BTK. In measurement locations that are in line of sight with the base stations, the RF-EMF value changes according to the measurement time. The RFEMF value measured in the afternoon is about 32% higher than at night. Statistical analysis of data showed that the long-term RF-EMF can be best expressed by Burr distribution. Unlike the studies in the literature, the change of RF-EMF during the day was examined and a new mathematical model was proposed. With the proposed model, the change of 24-hour RF-EMF during the day in the home environment can be determined with accuracy of up to 95% without the need for measurement using only 6-hour RF-EMF value. en_US
dc.language.iso eng en_US
dc.publisher GAZI UNIV, FAC ENGINEERING ARCHITECTURE ANKARA en_US
dc.relation.isversionof 10.17341/gazimmfd.641287 en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.subject RF-EMF EXPOSURE; RADIATION; ENVIRONMENTS; SCHOOLS; HOMES en_US
dc.subject Radiofrequency electromagnetic field; Long-term Radiofrequency electromagnetic field measurement; Base stations; ICNIRP en_US
dc.title Monitoring and modelling of long-term radiofrequency electromagnetic field levels en_US
dc.type article en_US
dc.relation.journal JOURNAL OF THE FACULTY OF ENGINEERING AND ARCHITECTURE OF GAZI UNIVERSITY en_US
dc.contributor.department Ordu Üniversitesi en_US
dc.identifier.volume 36 en_US
dc.identifier.issue 2 en_US
dc.identifier.startpage 669 en_US
dc.identifier.endpage 683 en_US


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account