DSpace Repository

ASSESSMENT OF HEAT GENERATION DURING IMPLANT INSERTION

Show simple item record

dc.contributor.author Cankaya, Soner
dc.contributor.author Keskiner, Ilker
dc.contributor.author Mercan, Ugur
dc.contributor.author Misir, Ferhat
dc.contributor.author Sumer, Mahmut
dc.date.accessioned 2022-08-29T07:19:59Z
dc.date.available 2022-08-29T07:19:59Z
dc.date.issued 2014
dc.identifier.uri http://doi.org/10.1016/j.prosdent.2013.12.011
dc.identifier.uri http://earsiv.odu.edu.tr:8080/xmlui/handle/11489/3085
dc.description.abstract Statement of problem. Many studies have investigated the heat generated during implant preparation, but data are needed to better predict heat generation during implant insertion. Purpose. The purpose of this study was to measure the heat generated during insertion of an implant at speeds of 30, 50, and 100 rpm, and with manual insertion. Material and methods. Sixty-four uniform fresh bovine femoral cortical bone specimens were used. After the cortical bone was drilled, 3 different implant insertion speeds and the manual insertion of the implant were evaluated for 2 different implant diameters. The temperature was measured with 2 Teflon-insulated, type K thermocouples. Data were analyzed by 2way ANOVA, and the Tukey honestly significant difference test (Gc=.05). Results. The highest thermal change for 4.1-mm-diameter implants was found at a speed of 100 rpm (9.81 C 2.29 C), and the lowest thermal change was 3.69 C 0.85 C at a speed of 30 rpm. A statistically significant difference was found between 100 rpm and the other 3 insertion procedures. The highest thermal change for a 4.8-mm-diameter implant was found at a speed of 100 rpm (8.79 C 1.53 C), and the lowest thermal change was 4.48 C 0.85 C at a speed of 30 rpm. No statistical difference was observed with manual, 30 rpm, and 50 rpm; however, a statistically significant difference was found between 100 rpm and the other 3 insertion procedures. Conclusions. Manual implant insertion and at speeds of 30 rpm and 50 rpm generated lower heat compared with insertion at 100 rpm. (J Prosthet Dent 20:14;112:522-525) en_US
dc.language.iso eng en_US
dc.publisher MOSBY-ELSEVIER360 PARK AVENUE SOUTH, NEW YORK, NY 10010-1710 en_US
dc.relation.isversionof 10.1016/j.prosdent.2013.12.011 en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.subject BONEOSSEOINTEGRATIONPLACEMENTSPEED en_US
dc.title ASSESSMENT OF HEAT GENERATION DURING IMPLANT INSERTION en_US
dc.type article en_US
dc.relation.journal JOURNAL OF PROSTHETIC DENTISTRY en_US
dc.contributor.department Ordu Üniversitesi en_US
dc.contributor.authorID 0000-0001-8056-1892 en_US
dc.identifier.volume 112 en_US
dc.identifier.issue 3 en_US
dc.identifier.startpage 522 en_US
dc.identifier.endpage 525 en_US


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account