DSpace Repository

Determination of hydrogen peroxide with an enzymeless amperometric sensor based on poly(vinylferrocene)-supported Ag nanoparticles

Show simple item record

dc.contributor.author Celebi, Mutlu Sonmez
dc.contributor.author Dumangoz, Mehmet
dc.contributor.author Kuralay, Filiz
dc.contributor.author Ozturk, Kubra
dc.date.accessioned 2022-08-17T07:10:17Z
dc.date.available 2022-08-17T07:10:17Z
dc.date.issued 2018
dc.identifier.uri http://doi.org/10.3906/kim-1801-58
dc.identifier.uri http://earsiv.odu.edu.tr:8080/xmlui/handle/11489/2699
dc.description.abstract An enzymeless electrochemical sensor for detection of low amounts of H2O2 with the aid of Ag nanoparticles supported on conducting poly(vinylferrocene) (PVF) film was developed. Experimental results revealed that contribution of Ag nanoparticles led to remarkable improvement by means of reduction potential and reduction current. Influence of experimental parameters (i.e. polymeric film thickness, concentration of Ag precursor, immersion time in precursor solution, reduction time, and reduction potential) were investigated. The Ag/PVF-modified electrode system was characterized physically by scanning electron microscopy. The results revealed that the sensor developed was easyto-prepare, economic, selective, and sensitive, with a fast response time of 3 s. The linear concentration range of the sensor was 0.1-50 mM, with a sensitivity of 14.1 mu A mM(-1) and a limit of detection of 0.94 mu M. Finally, interference effects of uric acid, ascorbic acid, dopamine, and glucose molecules were studied and no significant interference was observed at physiological levels. en_US
dc.language.iso eng en_US
dc.publisher SCIENTIFIC TECHNICAL RESEARCH COUNCIL TURKEY-TUBITAK, ATATURK BULVARI NO 221, KAVAKLIDERE, TR-06100 ANKARA, TURKEY Journal Information en_US
dc.relation.isversionof 10.3906/kim-1801-58 en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.subject Hydrogen peroxide determination; electrochemical sensor; poly(vinylferrocene); silver nanoparticles; modified electrode en_US
dc.title Determination of hydrogen peroxide with an enzymeless amperometric sensor based on poly(vinylferrocene)-supported Ag nanoparticles en_US
dc.type article en_US
dc.relation.journal TURKISH JOURNAL OF CHEMISTRY en_US
dc.contributor.department Ordu Üniversitesi en_US
dc.contributor.authorID 0000-0002-8816-6763 en_US
dc.identifier.volume 42 en_US
dc.identifier.issue 6 en_US
dc.identifier.startpage 1755 en_US
dc.identifier.endpage 1767 en_US