DSpace Repository

Paper Based Glucose Biosensor Using Graphene Modified with a Conducting Polymer and Gold Nanoparticles

Show simple item record

dc.contributor.author Gokoglan, Tugba Ceren
dc.contributor.author Kesik, Melis
dc.contributor.author Soylemez, Saniye
dc.contributor.author Toppare, Levent
dc.contributor.author Unalan, Husnu Emrah
dc.contributor.author Yuksel, Recep
dc.date.accessioned 2022-08-17T06:46:00Z
dc.date.available 2022-08-17T06:46:00Z
dc.date.issued 2017
dc.identifier.uri http://doi.org/10.1149/2.0791706jes
dc.identifier.uri http://earsiv.odu.edu.tr:8080/xmlui/handle/11489/2566
dc.description.abstract In this work a novel approach was reported for glucose detection using disposable paper based electrodes consisting graphene modified with a conducting polymer, glucose oxidase (GOx) and gold nanoparticles. For the first time, a conducting polymer; poly(9,9-di-(2-ethylhexyl)-fluorenyl-2,7-diyl)-end capped with 2,5-diphenyl-1,2,4-oxadiazole (PFLO) was spread over graphene coated papers and used as a matrix for glucose detection. To finalize the desired biosensor, the enzyme GOx was immobilized with gold nanoparticles (AuNPs) via physical adsorption technique. Oxygen consumption was followed at -0.7 V vs Ag wire in a 50 mM, pH 6.0 phosphate buffer. The amperometric response of the GOx/graphene/PFLO/AuNPs-modified electrode was found to be linearly proportional to the glucose concentration. The fabricated biosensor revealed a high sensitivity for glucose in a linear range from 0.1 to 1.5 mM with a low detection limit of 0.081 mM at a signal-to-noise ratio of 3. K-M(App), I-max, and sensitivity were calculated as 0.229 mM, 2.198 mu A, and 7.357 mu A/mM cm(2), respectively. Finally, the constructed disposable biosensor was successfully utilized for the determination of glucose in commercial beverages. (C) 2017 The Electrochemical Society. All rights reserved. en_US
dc.language.iso eng en_US
dc.publisher ELECTROCHEMICAL SOC INC, 65 SOUTH MAIN STREET, PENNINGTON, NJ 08534 USA en_US
dc.relation.isversionof 10.1149/2.0791706jes en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.subject ELECTROCHEMICAL SENSORS; BIOMOLECULE IMMOBILIZATION; PRUSSIAN-BLUE; OXIDASE; FILMS; ELECTRODES; POLYPYRROLE; COMPOSITE en_US
dc.title Paper Based Glucose Biosensor Using Graphene Modified with a Conducting Polymer and Gold Nanoparticles en_US
dc.type article en_US
dc.relation.journal JOURNAL OF THE ELECTROCHEMICAL SOCIETY en_US
dc.contributor.department Ordu Üniversitesi en_US
dc.contributor.authorID 0000-0001-8178-0165 en_US
dc.contributor.authorID 0000-0001-8178-0165 en_US
dc.contributor.authorID 0000-0002-8955-133X en_US
dc.contributor.authorID 0000-0003-3667-179X en_US
dc.identifier.volume 164 en_US
dc.identifier.issue 6 en_US
dc.identifier.startpage G59 en_US
dc.identifier.endpage G64 en_US


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account