DSpace Repository

Biosensing applications of titanium dioxide coated graphene modified disposable electrodes

Show simple item record

dc.contributor.author Bozduman, Ferhat
dc.contributor.author Kuralay, Filiz
dc.contributor.author Oksuz, Aysegul Uygun
dc.contributor.author Oksuz, Lutfi
dc.contributor.author Tunc, Selma
dc.date.accessioned 2022-08-17T06:43:58Z
dc.date.available 2022-08-17T06:43:58Z
dc.date.issued 2016
dc.identifier.uri http://doi.org/10.1016/j.talanta.2016.07.037
dc.identifier.uri https://www.sciencedirect.com/science/article/pii/S0039914016305409?via%3Dihub
dc.identifier.uri http://earsiv.odu.edu.tr:8080/xmlui/handle/11489/2551
dc.description.abstract In the present work, preparation of titanium dioxide coated graphene (TiO2/graphene) and the use of this nanocomposite modified electrode for electrochemical biosensing applications were detailed. The nanocomposite was prepared with radio frequency (rf) rotating plasma method which serves homogeneous distribution of TiO2 onto graphene. TiO2/graphene was characterized with scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDS) and X-ray diffraction (XRD) analysis. Then, this nanocomposite was dissolved in phosphate buffer solution (pH 7.4) and modified onto disposable pencil graphite electrode (PGE) by dip coating for the investigation of the biosensing properties of the prepared electrode. TiO2/graphene modified PGE was characterized with SEM, EDS and cyclic voltammetry (CV). The sensor properties of the obtained surface were examined for DNA and DNA-drug interaction. The detection limit was calculated as 1.25 mg L-1 (n=3) for double-stranded DNA (dsDNA). RSD% was calculated as 2.4% for three successive determinations at 5 mg L-1 dsDNA concentration. Enhanced results were obtained compared to the ones obtained with graphene and unmodified (bare) electrodes. (C) 2016 Elsevier B.V. All rights reserved. en_US
dc.language.iso eng en_US
dc.publisher ELSEVIER, RADARWEG 29, 1043 NX AMSTERDAM, NETHERLANDS en_US
dc.relation.isversionof 10.1016/j.talanta.2016.07.037 en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.subject REDUCED GRAPHENE; CARBON NANOTUBES; TIO2; COMPOSITES; DNA; NANOPARTICLES; FILM en_US
dc.subject TiO2/graphene nanocomposite; Rotating plasma; Electrochemistry; TiO2/graphene nanocomposite modified electrode; DNA; DNA-drug interaction en_US
dc.title Biosensing applications of titanium dioxide coated graphene modified disposable electrodes en_US
dc.type article en_US
dc.relation.journal TALANTA en_US
dc.contributor.department Ordu Üniversitesi en_US
dc.contributor.authorID 0000-0002-2669-021X en_US
dc.contributor.authorID 0000-0003-0356-9692 en_US
dc.identifier.volume 160 en_US
dc.identifier.startpage 325 en_US
dc.identifier.endpage 331 en_US


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account