DSpace Repository

The evaluation of palatal bone thickness for implant insertion with cone beam computed tomography

Show simple item record

dc.contributor.author Caliskan, A.
dc.contributor.author Cankaya, S.
dc.contributor.author Karoz, T. B.
dc.contributor.author Sumer, A. P.
dc.contributor.author Sumer, M.
dc.contributor.author Uzun, C.
dc.date.accessioned 2022-08-16T11:56:59Z
dc.date.available 2022-08-16T11:56:59Z
dc.date.issued 2016
dc.identifier.uri http://doi.org/10.1016/j.ijom.2015.09.012
dc.identifier.uri https://www.sciencedirect.com/science/article/pii/S0901502715013296?via%3Dihub
dc.identifier.uri http://earsiv.odu.edu.tr:8080/xmlui/handle/11489/2060
dc.description.abstract The palate is an alternative anchoring site for orthodontic implants and screws. The use of osseointegrated implants in the intermaxillary suture has recently been described as a fast, effective, and low-cost technique for patients with atrophy of the maxillae. The aim of this study was to use cone beam computed tomography (CBCT) to evaluate the thickness of the bone surrounding the intermaxillary suture in relation to the insertion of osseointegrated implants. CBCT images of 144 patients (72 males, 72 females) aged 35-86 years were evaluated. The vertical bone height of the intermaxillary suture was measured using coronal and sagittal Images 5, 10, 15, 20, and 25 mm posterior to the incisive foramen. The mean bone thicknesses from the anterior to the posterior region were 5.59, 4.38, 3.91, 3.95, and 3.94 mm, respectively. Bone thickness was significantly different among the five anteroposterior areas of the suture, but there were no significant differences between males and females, or among age groups. The highest part of the intermaxillary suture was in the anterior region. Three-dimensional imaging is recommended to accurately identify palate bone thickness for implant placement. en_US
dc.language.iso eng en_US
dc.publisher CHURCHILL LIVINGSTONE, JOURNAL PRODUCTION DEPT, ROBERT STEVENSON HOUSE, 1-3 BAXTERS PLACE, LEITH WALK, EDINBURGH EH1 3AF, MIDLOTHIAN, SCOTLAND en_US
dc.relation.isversionof 10.1016/j.ijom.2015.09.012 en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.subject CBCT; palatal implants; palate en_US
dc.subject PLACEMENT; ADOLESCENTS; ANCHORAGE; ADULTS en_US
dc.title The evaluation of palatal bone thickness for implant insertion with cone beam computed tomography en_US
dc.type article en_US
dc.relation.journal INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY en_US
dc.contributor.department Ordu Üniversitesi en_US
dc.contributor.authorID 0000-0001-8056-1892 en_US
dc.identifier.volume 45 en_US
dc.identifier.issue 2 en_US
dc.identifier.startpage 216 en_US
dc.identifier.endpage 220 en_US


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account