DSpace Repository

In Vitro Comparative Analysis of Fracture Resistance in Inlay Restoration Prepared with CAD-CAM and Different Systems in the Primary Teeth

Show simple item record

dc.contributor.author Derelioglu, Sera
dc.contributor.author Simsek, Huseyin
dc.date.accessioned 2022-08-16T05:53:08Z
dc.date.available 2022-08-16T05:53:08Z
dc.date.issued 2016
dc.identifier.uri http://doi.org/10.1155/2016/4292761
dc.identifier.uri https://www.hindawi.com/journals/bmri/2016/4292761/
dc.identifier.uri http://earsiv.odu.edu.tr:8080/xmlui/handle/11489/1645
dc.description.abstract Objective. The aim of this study was to compare to fracture resistance test of inlay restorations prepared using direct inlay technique (Gradia (R) Direct Composite) and Indirect Restoration System (R) (Gradia Indirect Composite) and CAD/CAD system(Vita Enamic (R) Block). Study Design. 48 noncarious extracted maxillary second primary molars were randomly divided into 4 groups with 12 in each group. All the teeth were prepared based on inlay class II preparations except for the control group. Other groups were restored with Gradia Direct Composite, Gradia Indirect Composite, and Vita Enamic Block, respectively. All restorations were cemented self-adhesive dual cure resin (3M Espe, RelyX (TM) Unicem Aplicap). A fracture test was performed using a compressive load. Results were analyzed using one-way analysis of variance and Duncan's post hoc multiple comparison tests (alpha = 0.05). Results. Vita Enamic Block and Gradia Indirect Composite showed significantly higher fracture resistance than Gradia Direct Composite (p < 0.05). There was no significant difference fracture resistance between Vita Enamic Block and Gradia Indirect Composite (p > 0.05). All restorations tested led to a significant reduction in fracture resistance (p < 0.05). Conclusion. In inlay restorations, Indirect Restoration Systems and CAD/CAM systems were applied successfully together with the self-adhesive dual cure resin cements in primary molars. en_US
dc.language.iso eng en_US
dc.publisher HINDAWI LTD, ADAM HOUSE, 3RD FLR, 1 FITZROY SQ, LONDON, W1T 5HF, ENGLAND en_US
dc.relation.isversionof 10.1155/2016/4292761 en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.title In Vitro Comparative Analysis of Fracture Resistance in Inlay Restoration Prepared with CAD-CAM and Different Systems in the Primary Teeth en_US
dc.type article en_US
dc.relation.journal BIOMED RESEARCH INTERNATIONAL en_US
dc.contributor.department Ordu Üniversitesi en_US
dc.contributor.authorID 0000-0001-5192-923X en_US
dc.contributor.authorID 0000-0002-9868-8266 en_US
dc.identifier.volume 2016 en_US
dc.identifier.issue 4292761 en_US


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account