Please use this identifier to cite or link to this item: http://earsiv.odu.edu.tr:8080/xmlui/handle/11489/4398
Full metadata record
DC FieldValueLanguage
dc.contributor.authorCelik, Huzeyfe-
dc.contributor.authorSoylemez, Saniye-
dc.date.accessioned2024-03-15T11:08:33Z-
dc.date.available2024-03-15T11:08:33Z-
dc.date.issued2023-
dc.identifier.citationCelik, H., Soylemez, S. (2023). An Electrochemical Acetylcholinesterase Biosensor Based on Fluorene(bisthiophene) Comprising Polymer for Paraoxon Detection. Electroanalysis, 35(3). https://doi.org/10.1002/elan.202200271en_US
dc.identifier.issn1040-0397-
dc.identifier.issn1521-4109-
dc.identifier.urihttp://dx.doi.org/10.1002/elan.202200271-
dc.identifier.urihttps://www.webofscience.com/wos/woscc/full-record/WOS:000849808200001-
dc.identifier.urihttp://earsiv.odu.edu.tr:8080/xmlui/handle/11489/4398-
dc.descriptionWoS Categories: Chemistry, Analytical; Electrochemistryen_US
dc.descriptionWeb of Science Index: Science Citation Index Expanded (SCI-EXPANDED)en_US
dc.descriptionResearch Areas: Chemistry; Electrochemistryen_US
dc.description.abstractIn this study, a novel conductive polymer comprising biosensor based on poly-2,2 '-(9,9-dioctyl-9 h-fluorene-2,7-diyl)bistiophene (Poly(BT)) and acetylcholinesterase (AChE) was reported for the determination of paraoxon. This practical biosensor allowed to catalyze electrochemical oxidation of acetylthiocholine (+0.6 V vs. Ag reference). The detection range for acetylcholine chloride (AThCl) with Poly(BT)/AChE was found to be 0.025-4 mM. In pesticide analysis, wide linear ranges from 0.5 to 1 mu g/L and 1 to 14 mu g/L, and a low detection limit of 0.033 mu g/L were estimated. Under optimum operating conditions, the developed biosensor was used for pesticide detection in milk and tap water samples, effectively.en_US
dc.description.sponsorshipOrdu University BAP project [B-2111]en_US
dc.language.isoengen_US
dc.publisherWILEY-V C H VERLAG GMBH-WEINHEIMen_US
dc.relation.isversionof10.1002/elan.202200271en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectElectrochemical Biosensor, Conjugated Polymer, Acetylcholinesterase, Enzyme Immobilization, Organophosphorus Pesticidesen_US
dc.subjectCARBON NANOTUBES, AMPEROMETRIC DETECTION, CONJUGATED POLYMER, PESTICIDES, ORGANOPHOSPHATE, IMMOBILIZATION, NANOPARTICLES, ELECTRODES, SURFACE, WATERen_US
dc.titleAn Electrochemical Acetylcholinesterase Biosensor Based on Fluorene(bisthiophene) Comprising Polymer for Paraoxon Detectionen_US
dc.typearticleen_US
dc.relation.journalELECTROANALYSISen_US
dc.contributor.departmentOrdu Üniversitesien_US
dc.contributor.authorID0000-0002-8955-133Xen_US
dc.contributor.authorID0000-0002-8955-133Xen_US
dc.identifier.volume35en_US
dc.identifier.issue3en_US
Appears in Collections:Kimya

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.