Please use this identifier to cite or link to this item:
http://earsiv.odu.edu.tr:8080/xmlui/handle/11489/3508
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kurnaz, Cetin | - |
dc.contributor.author | Mutlu, Mustafa | - |
dc.date.accessioned | 2023-01-06T11:15:56Z | - |
dc.date.available | 2023-01-06T11:15:56Z | - |
dc.date.issued | 2021 | - |
dc.identifier.citation | Kurnaz, C., Mutlu, M. (2021). Monitoring and modelling of long-term radiofrequency electromagnetic field levels. Journal of the Faculty of Engineering and Architecture of Gazi University, 36(2), 669-683.Doi:10.17341/gazimmfd.641287 | en_US |
dc.identifier.isbn | 1300-1884 | - |
dc.identifier.isbn | 1304-4915 | - |
dc.identifier.uri | http://dx.doi.org/10.17341/gazimmfd.641287 | - |
dc.identifier.uri | https://www.webofscience.com/wos/woscc/full-record/WOS:000626722500007 | - |
dc.identifier.uri | http://earsiv.odu.edu.tr:8080/xmlui/handle/11489/3508 | - |
dc.description | WoS Categories : Engineering, Multidisciplinary Web of Science Index : Science Citation Index Expanded (SCI-EXPANDED) Research Areas : Engineering Open Access Designations : gold, Green Submitted | en_US |
dc.description.abstract | In this study, in order to determine the radiofrequency electromagnetic field (RF-EMF) level exposed in the home environment and to model its change, 24-hour RF-EMF measurements were performed in the frequency range of 100 kHz to 3 GHz. In measurements, the highest RF-EMF value was recorded as 17.31 V/m, which is below the limit values determined by ICNIRP and BTK. In measurement locations that are in line of sight with the base stations, the RF-EMF value changes according to the measurement time. The RFEMF value measured in the afternoon is about 32% higher than at night. Statistical analysis of data showed that the long-term RF-EMF can be best expressed by Burr distribution. Unlike the studies in the literature, the change of RF-EMF during the day was examined and a new mathematical model was proposed. With the proposed model, the change of 24-hour RF-EMF during the day in the home environment can be determined with accuracy of up to 95% without the need for measurement using only 6-hour RF-EMF value. | en_US |
dc.language.iso | eng | en_US |
dc.publisher | GAZI UNIV, FAC ENGINEERING ARCHITECTURE ANKARA | en_US |
dc.relation.isversionof | 10.17341/gazimmfd.641287 | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | RF-EMF EXPOSURE; RADIATION; ENVIRONMENTS; SCHOOLS; HOMES | en_US |
dc.subject | Radiofrequency electromagnetic field; Long-term Radiofrequency electromagnetic field measurement; Base stations; ICNIRP | en_US |
dc.title | Monitoring and modelling of long-term radiofrequency electromagnetic field levels | en_US |
dc.type | article | en_US |
dc.relation.journal | JOURNAL OF THE FACULTY OF ENGINEERING AND ARCHITECTURE OF GAZI UNIVERSITY | en_US |
dc.contributor.department | Ordu Üniversitesi | en_US |
dc.identifier.volume | 36 | en_US |
dc.identifier.issue | 2 | en_US |
dc.identifier.startpage | 669 | en_US |
dc.identifier.endpage | 683 | en_US |
Appears in Collections: | Makale Koleksiyonu |
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.