Please use this identifier to cite or link to this item: http://earsiv.odu.edu.tr:8080/xmlui/handle/11489/2418
Full metadata record
DC FieldValueLanguage
dc.contributor.authorAtmaca, Husnu-
dc.contributor.authorBektas, Osman-
dc.contributor.authorGunaydin, Zeki Yuksel-
dc.contributor.authorKaragoz, Ahmet-
dc.contributor.authorKaya, Ahmet-
dc.contributor.authorSahin, Osman-
dc.contributor.authorVural, Asli-
dc.date.accessioned2022-08-17T05:50:50Z-
dc.date.available2022-08-17T05:50:50Z-
dc.date.issued2015-
dc.identifier.urihttps://pubmed.ncbi.nlm.nih.gov/26204686/-
dc.identifier.urihttp://earsiv.odu.edu.tr:8080/xmlui/handle/11489/2418-
dc.description.abstractBackground and aim of the study: Percutaneous balloon mitral valvuloplasty (PMBV) has an established role in the treatment of rheumatic mitral stenosis. The study aim was to evaluate the effects of PMBV on left ventricular function in patients with rheumatic mitral stenosis (MS) by using strain and strain rate imaging modalities. Methods: The study included 30 consecutive patients (21 women, nine men; mean age 44 +/- 14 years) with moderate to severe MS. Left ventricular long-axis strain and strain rate color tissue Doppler imaging of the septal, lateral, inferior and anterior basal segments were performed one day before and seven days after PMBV. Results: Compared with pretreatment findings, lateral systolic strain (-13.4 +/- 2.9% versus -18.4 +/- 3.9%; p = 0.024), inferior systolic strain (-14.7 +/- 2.3% versus -17.6 +/- 2.1%; p = 0.016), anterior systolic strain (-15.2 +/- 2.4% versus -17.2 +/- 2.2%; p = 0.02), and septal systolic strain (-15.7 +/- 1.6% versus -18.1 +/- 1.9%; p = 0.018) values were significantly increased after the procedure, but no significant change was observed in strain rate analysis. Conclusion: A rapid improvement in strain values after PMBV in patients with isolated MS showed that the LV systolic dysfunction in isolated MS is strongly associated with impaired hemodynamic parameters. Significantly increased strain values can be added to the criteria of successful PMBV.en_US
dc.language.isoengen_US
dc.publisherI C R PUBLISHERSCRISPIN HOUSE, 12/A SOUTH APPROACH, MOOR PARK, NORTHWOOD HA6 2ET, ENGLANDen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectTISSUE DOPPLERWALL-MOTIONen_US
dc.titleEvaluation of the Effect of Percutaneous Mitral Balloon Valvuloplasty on Left Ventricular Systolic Function via Strain and Strain Rate in Patients with Isolated Rheumatic Mitral Stenosisen_US
dc.typearticleen_US
dc.relation.journalJOURNAL OF HEART VALVE DISEASEen_US
dc.contributor.departmentOrdu Üniversitesien_US
dc.contributor.authorID0000-0001-9779-7578en_US
dc.contributor.authorID0000-0001-9845-7938en_US
dc.contributor.authorID0000-0002-6616-9891en_US
dc.identifier.volume24en_US
dc.identifier.issue2en_US
dc.identifier.startpage204en_US
dc.identifier.endpage209en_US
Appears in Collections:Dahili Tıp Bilimleri

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.