Please use this identifier to cite or link to this item: http://earsiv.odu.edu.tr:8080/xmlui/handle/11489/1992
Full metadata record
DC FieldValueLanguage
dc.contributor.authorAkdeniz, Esra-
dc.contributor.authorAytekin, Kursad-
dc.contributor.authorBas, Orhan-
dc.contributor.authorCoskun, Zafer Unsal-
dc.contributor.authorDanisman, Murat-
dc.contributor.authorEsenyel, Cem Zeki-
dc.contributor.authorSahiner, Goksel Gultekin-
dc.contributor.authorTakir, Selcuk-
dc.contributor.authorUysal, Murat-
dc.date.accessioned2022-08-16T11:42:44Z-
dc.date.available2022-08-16T11:42:44Z-
dc.date.issued2020-
dc.identifier.urihttp://doi.org/10.1016/j.vascn.2019.106658-
dc.identifier.urihttp://earsiv.odu.edu.tr:8080/xmlui/handle/11489/1992-
dc.description.abstractIntroduction: The injection amount of solutions differs in wide ranges, from 20 to 200 mu L in intraarticular injections experiments that was carried out with rats. The 10-fold difference between applied volumes is not acceptable since injection errors might affect the outcomes of the studies significantly. The excessive amount of solution that was injected into the knee joint of rats might end up with leakage of the solution from injection aperture, and damage the articular structures etc. In our preliminary experiments, we mentioned problems during the injection of excessive amount of solution into the rat knee joint. The main purpose of the present study, which was performed with rat knee joints, was to evaluate the applicability of different amounts of solutions used in experiments and to determine the optimal volume for intraarticular injection in rats. Methods: The volume of 100 mu L water-based stain was administered into knee joints of non-living rats. The legs were dissected to evaluate the possible presence of injected solution outside the knee joint. Then, the decreasing volumes (100 mu L, 50 mu L, 40 mu L and 30 mu L) of X-ray contrast solution (lobitridol) were applied into the knees of living rats to investigate whether systemic circulation acts on the leakage outside the joint. The X-ray images of all these joints were also taken to confirm the results. Results: In nonliving rats, the place where water-based strain overflow from the knee joint was pointed out. The place of leakage is where the tendo musculi extensor digitorum longus leaves outside the joint. In living rats, by using contrast solution, an overflow was noticed in the subdermal place with the intraarticular injection volumes of 100 mu L, 50 mu L, and 40 mu L. No overflow was observed with the intraarticular injection volumes of 30 mu L X-ray contrast solution. Discussion: In conclusion, the injection volume for the knee joints of rats should not exceed the 30 mu L for optimum efficiency.en_US
dc.language.isoengen_US
dc.publisherELSEVIER SCIENCE INC, STE 800, 230 PARK AVE, NEW YORK, NY 10169 USAen_US
dc.relation.isversionof10.1016/j.vascn.2019.106658en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectIntraarticular injection; Overflow; Rat; Knee; Joint disorderen_US
dc.subjectMODEL; ARTHRITIS; ACIDen_US
dc.titleEvaluation of different intraarticular injection volumes to assess optimum efficient amount; an experimental study in rat knee jointsen_US
dc.typearticleen_US
dc.relation.journalJOURNAL OF PHARMACOLOGICAL AND TOXICOLOGICAL METHODSen_US
dc.contributor.departmentOrdu Üniversitesien_US
dc.contributor.authorID0000-0002-7449-2699en_US
dc.identifier.volume101en_US
Appears in Collections:Temel Tıp Bilimleri

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.