Please use this identifier to cite or link to this item:
http://earsiv.odu.edu.tr:8080/xmlui/handle/11489/1686
Title: | Effects of Laser Treatment on the Bond Strength of Differently Sintered Zirconia Ceramics |
Authors: | Dede, Dogu Omur Dede, Figen Ongoz Rona, Nergiz Yenisey, Murat Ordu Üniversitesi 0000-0001-8101-3599 0000-0002-4211-3359 0000-0003-1021-5702 0000-0003-2242-1482 |
Keywords: | SURFACE TREATMENTS; RESIN CEMENT; FLEXURAL STRENGTH; AIR ABRASION; GRAIN-SIZE; TEMPERATURE |
Issue Date: | 2016 |
Publisher: | MARY ANN LIEBERT, INC, 140 HUGUENOT STREET, 3RD FL, NEW ROCHELLE, NY 10801 USA |
Abstract: | Objective: The purpose of this study was to investigate the effects of carbon dioxide (CO2) and Erbium-doped yttrium aluminum garnet (Er:YAG) laser irradiations on the shear bond strength (SBS) of differently sintered zirconia ceramics to resin cement. Materials and methods: Eighty zirconia specimens were prepared, sintered in two different periods (short = Ss, long = Ls), and divided into four treatment groups (n = 10 each). These groups were (a) untreated (control), (b) Er: YAG laser irradiated with 6W power for 5 sec, (c) CO2 laser with 2W power for 10 sec, (d) CO2 laser with 4W power for 10 sec. Scanning electron microscope (SEM) images were recorded for each of the eight groups. Eighty composite resin discs (3 x 3 mm) were fabricated and cemented with an adhesive resin cement to ceramic specimens. The SBS test was performed after specimens were stored in water for 24 h by an universal testing machine at a crosshead speed of 1 mm/min. Data were statistically analyzed with two way analysis of variance (ANOVA) and Tukey honest significant difference (HSD) test (a = 0.05). Results: According to the ANOVA, the sintering time, surface treatments and their interaction were statistically significant (p < 0.05). Although each of the laser-irradiated groups were significantly higher than the control groups, there was no statistically significant difference among them (p > 0.05). Conclusions: Variation in sintering time from 2.5 to 5.0 h may have influenced the SBS of Yttrium-stabilized tetragonal zirconia polycrystalline (Y-TZP) ceramics. Although CO2 and Er: YAG laser irradiation techniques may increase the SBS values of both tested zirconia ceramics, they are recommended for clinicians as an alternative pretreatment method. |
URI: | http://doi.org/10.1089/pho.2015.4064 https://www.liebertpub.com/doi/full/10.1089/pho.2015.4064 http://earsiv.odu.edu.tr:8080/xmlui/handle/11489/1686 |
Appears in Collections: | Protetik Diş Tedavisi |
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.