Please use this identifier to cite or link to this item:
http://earsiv.odu.edu.tr:8080/xmlui/handle/11489/1609
Title: | Comparison of direct and indirect skeletal anchorage systems combined with 2 canine retraction techniques |
Authors: | Bayram, Mehmet Ozkan, Serkan Ordu Üniversitesi 0000-0002-7506-9649 |
Keywords: | SLIDING MECHANICS; IMPLANT ANCHORAGE |
Issue Date: | 2016 |
Publisher: | MOSBY-ELSEVIER, 360 PARK AVENUE SOUTH, NEW YORK, NY 10010-1710 USA |
Abstract: | Introduction: We compared the effectiveness of 2 canine retraction springs and anchorage systems (direct and indirect skeletal anchorage) in patients requiring first premolar extractions and maximum anchorage in the maxilla. Methods: Thirty-six patients were included (17 male, 19 female; mean age, 16.8 +/- 2.4 years). A mini-implant-supported Nance appliance with indirect skeletal anchorage system was used in 18 patients and a mini-implant-supported direct skeletal anchorage system in the remaining patients. In each patient, a segmental retraction arch with a reverse closing loop was applied to a maxillary canine, and a Ladanyi spring (Dentaurum, Ispringen, Germany) was applied to the other canine randomly after extraction of the maxillary first premolars. The retraction process was continued until a Class I canine relationship was obtained. Lateral cephalometric films and orthodontic casts taken before and after retraction in the distalization process were used to evaluate changes during canine distalization. The measurements were statistically evaluated using paired and independent t tests with 95% confidence intervals. Results: The reverse closing loop and the Ladanyi spring were found to be effective in canine distalization (P < 0.001). There were no statistically significant differences between the reverse closing loop and the Ladanyi spring with regard to canine distalization rates (P >= 0.05). Both systems were effective in providing maximum anchorage (P >= 0.05); no statistically significant differences were detected in molar anchorage loss rates between the 2 methods (P >= 0.05). Conclusions: These 2 systems can be used during segmental distalization of canines requiring maximum anchorage with no significant anchorage loss. |
URI: | http://doi.org/10.1016/j.ajodo.2016.04.023 https://www.sciencedirect.com/science/article/pii/S0889540616303924?via%3Dihub http://earsiv.odu.edu.tr:8080/xmlui/handle/11489/1609 |
Appears in Collections: | Ortodonti |
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.