Please use this identifier to cite or link to this item:
http://earsiv.odu.edu.tr:8080/xmlui/handle/11489/1589
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Keskin, Cangul | - |
dc.contributor.author | Sariyilmaz, Evren | - |
dc.date.accessioned | 2022-08-16T05:37:47Z | - |
dc.date.available | 2022-08-16T05:37:47Z | - |
dc.date.issued | 2018 | - |
dc.identifier.uri | http://doi.org/10.4274/meandros.24008 | - |
dc.identifier.uri | http://earsiv.odu.edu.tr:8080/xmlui/handle/11489/1589 | - |
dc.description.abstract | Objective: Extrusion of irrigant and debris into the periapical tissues is a potential risk for flare-ups during root canal treatment. The aim of this study was to evaluate the apically extruded debris and sodium hypochlorite during XP-Endo Finisher (XP-Endo) file use and compare with final irrigation techniques. The tested null hypothesis in this study was that there was no difference among the irrigation techniques. Materials and Methods: An agar gel model was prepared for 80 extracted single rooted human mandibular premolar teeth, which were prepared up to the apical size of #40. The samples were divided into four groups according to the final irrigation regime: conventional syringe irrigation, XP-Endo, passive ultrasonic irrigation (PUI), and EndoActivator (EA). The test apparatus was weighed before and after the experiment, and the amount of apically extruded debris and irrigant was calculated. Results: There was minimal irrigant and debris extrusion in all groups. No significant difference among the tested groups was detected (p>0.05). Conclusion: Using the PUI, XP-Endo file, or EA according to the manufacturers' instruction does not increase the extrusion risk. Keywords | en_US |
dc.language.iso | eng | en_US |
dc.publisher | GALENOS YAYINCILIK, ERKAN MOR, MOLLA GURANI CAD 21-1, FINDIKZADE, ISTANBUL 34093, TURKEY | en_US |
dc.relation.isversionof | 10.4274/meandros.24008 | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | XP-Endo Finisher; passive ultrasonic irrigation; sonic irrigation; apical extrusion | en_US |
dc.title | Apical Extrusion of Debris and Irrigant Using XP-Endo Finisher, EndoActivator, Passive Ultrasonic Irrigation or Syringe Irrigation | en_US |
dc.type | article | en_US |
dc.relation.journal | MEANDROS MEDICAL AND DENTAL JOURNAL | en_US |
dc.contributor.department | Ordu Üniversitesi | en_US |
dc.contributor.authorID | 0000-0003-1711-7056 | en_US |
dc.identifier.volume | 19 | en_US |
dc.identifier.issue | 2 | en_US |
dc.identifier.startpage | 127 | en_US |
dc.identifier.endpage | 131 | en_US |
Appears in Collections: | Endodonti |
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.