Please use this identifier to cite or link to this item:
http://earsiv.odu.edu.tr:8080/xmlui/handle/11489/1584
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Cakici, Fatih | - |
dc.contributor.author | Ersoy, Ibrahim | - |
dc.contributor.author | Gunduz, Hicran Ates | - |
dc.contributor.author | Karatas, Ertugrul | - |
dc.contributor.author | Kol, Elif | - |
dc.contributor.author | Uygun, Ahmet Demirhan | - |
dc.date.accessioned | 2022-08-16T05:36:20Z | - |
dc.date.available | 2022-08-16T05:36:20Z | - |
dc.date.issued | 2016 | - |
dc.identifier.uri | http://doi.org/10.1111/aor.12675 | - |
dc.identifier.uri | https://onlinelibrary.wiley.com/doi/10.1111/aor.12675 | - |
dc.identifier.uri | http://earsiv.odu.edu.tr:8080/xmlui/handle/11489/1584 | - |
dc.description.abstract | The aim of the present study was to compare the effects of ProTaper Gold, WaveOne Gold, ProTaper Universal, and WaveOne instruments on the amount of apically extruded debris. Eighty mandibular premolar teeth with straight root canals were selected and assigned to four groups (n=20). The root canals were instrumented using ProTaper Gold, WaveOne Gold, ProTaper Universal, and WaveOne systems. Eppendorf tubes containing apically extruded debris were weighed three times, and mean values were calculated. The net mass of the extruded debris was calculated by subtracting the initial mass from the final mass. The groups were compared using one-way analysis of variance and Tukey's post hoc tests at a significance level of P<0.05. The PTG group extruded less debris than the PTU group, and the WOG group extruded less debris than the WO group (P<0.05). All the instrumentation systems tested in the present study were associated with apical extrusion of debris. | en_US |
dc.language.iso | eng | en_US |
dc.publisher | WILEY, 111 RIVER ST, HOBOKEN 07030-5774, NJ USA | en_US |
dc.relation.isversionof | 10.1111/aor.12675 | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Debris; ProTaper Gold; WaveOne Gold | en_US |
dc.subject | RECIPROCATING SINGLE-FILE; SELF-ADJUSTING FILE; EXTRUSION; SYSTEMS | en_US |
dc.title | Influence of Instruments Used in Root Canal Preparation on Amount of Apically Extruded Debris | en_US |
dc.type | article | en_US |
dc.relation.journal | ARTIFICIAL ORGANS | en_US |
dc.contributor.department | Ordu Üniversitesi | en_US |
dc.contributor.authorID | 0000-0002-8147-2661 | en_US |
dc.identifier.volume | 40 | en_US |
dc.identifier.issue | 8 | en_US |
dc.identifier.startpage | 774 | en_US |
dc.identifier.endpage | 777 | en_US |
Appears in Collections: | Endodonti |
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.